11.2 STORAGE
The appliance, with or without its packaging, should be carefully stored inside warehouses or in areas protected from
the weather and from direct sunlight, at a temperature between
0
and
+40
°C.
11.3 HANDLING
The apparatus should only be handled using a fork lift truck
of a sufficient capacity for its weight, and operated by qualified personnel: during such operations,
the apparatus must be positioned on the pallet supplied
11.4
ENVIRONMENTAL CONDITIONS
ATTENTION
A dry room that can be ventilated is the suitable location for the appliance's installation. There should be
a good air flow around the compressor/condensing unit. Therefore the area around the unit should not be
obstructed by boxes or other objects. Place the equipment away from sources of heat (radiators, heaters
of any kind, etc.)
and far from the influence of continuous air movement (caused by fans, air conditioning
units, etc.). If it is unavoidable to install near a heat source, use a suitable insulating plate. Also avoid
exposure to direct solar irradiation
; all of this causes the temperature inside the refrigerated compartment
to rise with negative consequences on operation and energy consumption. The apparatus must not be used
outside nor be exposed to rain.
11.5
ELECTRICAL CONNECTION
ATTENTION
Check that the network voltage matches the one displayed on the identification
plate of the appliance, and that the power is adequate. Check on the socket that the power supply voltage
provides rated voltage (±10%) when you start up the compressor. The plug should be directly connected
to the electrical socket. It is forbidden to connect the plug to the socket by means of multiple socket
extensions or adaptors. The plant power supply socket must be fitted with a disconnection device from the
mains electricity (dimensioned to the load and in compliance with Standards in force), which guarantees
complete disconnection in category III (3) over-voltage conditions and therefore protects the circuits against
earth faults, overloads and short circuits. Do not route the electricity cable in passageways.
ATTENTION
Earthing is necessary and
mandatory
by law.
MAX
MIN