Cover - open or close pool cover, status will be also shown on swimming
pool model. Manipulation with pool cover is password protected. Password is 183. During opening or
closing pool cover operator must have direct visibility of the pool.
AUX 1 or 2 - Turn ON or OFF AUX 1 or 2, icon can vary based on configured
type in Settings.
5.4
Dashboard
Offers complete overview of swimming pool equipment, technologies statuses including, circuit breakers,
water quality, sensors connection states and condition, various alarms, equipment runtimes and next
service intervals.
Explanation of used icons:
5.4.1
Main
Pool Mode:
Shows current pool mode set on LVLØ. In use = automatic processes are running, closed
= automatic processes are stopped.
Service required: Is main alert. If this alert is active, interaction with system is needed. This alert is activated
if any of the system alerts is active. Check bellow alerts for more details. Pool border on Home screen is
changing color green and red based on this metric.
Water quality long term: If measured water quality values are outside defined parameters for longer period
(3days) when system is active, alarm will be raised. Manual intervention is needed. This metric is changing
water quality status on Home screen.
Technology: This alert is triggered when technology parts have active alert. This is combining, circuit
breakers monitoring, sensors connection failures or malfunction. Check bellow for more details.
Regular service: If any defined service or maintenance interval is reached, this alert will be activated. Check
corresponding section for details.
LVLØ hardware: LVLØ is a complex hardware therefore an internal heartbeat is build-in. This will raise an
alarm when the hardware communication flow is broken. Try to reset the device when such failure occurs.
Contact ISA technical support when the error persists after restart or is reoccurring.
Forced filtration 24h: Shows the status of forced filtration that can be triggered only via LVLØ front panel.
Forced filtration 48h: Shows the status of forced filtration that can be triggered only via LVLØ front panel.
5.4.2
Circuit breakers
OK
Warning
Error
Active
Inactive
Valve closed
Valve open
Connected
Disconnected/Faulty sensor