14
GELATO
SHOW
2
USE AND MAINTENANCE MANUAL
428000485237
EN
OPERATION
FREQUENCY
ROUTINE
EXTRAORDINARY
AUTHORISED
PERSONNEL
Cleaning the external surfaces
Depending upon Use and Necessity
X
User
Cleaning the accessible internal parts
(without the use of tools)
Depending upon Use and Necessity
X
User
Check power cable,
plugs and sockets
Monthly
Every 6 months
X
User
Check integrity of sealing gaskets
Monthly
X
User
Cleaning the defrosting water water collection tray
Every six months
Depending upon use and necessity
X
Technical
Assistance
Condenser cleaning
Monthly
Every 6 months
X
Technical
Assistance
Control compressor oil level
(if present)
Every 6 months
X
Technical
Assistance
Air tank draining
(if present)
Every 6 months
X
Technical
Assistance
Check pneumatic connections
(if present)
Every 6 months
X
Technical
Assistance
Check the integrity of the chiller system piping
Every 6 months
X
Technical
Assistance
Inspect cables and internal power connections
Every 6 months
X
Technical
Assistance
Cleaning condensate drying sponges
(if present)
Every 6 months
X
Technical
Assistance
Replacing the lamps / LED (if present)
X
Technical
Assistance
Control panel replacement (ECU - thermal switch - etc.)
X
Technical
Assistance
Power cable, plug and/or socket replacement
X
Technical
Assistance
9. MAINTENANCE
The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table
below, calling the authorised Technical After-sales assistance when indicated.
Attention
After every maintenance operation it is mandatory to perform all electric safety tests in compliance
with IEC EN 50106.
Содержание 120 RV TB