44 

5.1.10.4

 

System Warning – Event Selection 

SYSLOG and SMTP are the two warning methods supported by the system. Check the corresponding 
box to enable the system event warning method required. Please note that the check box cannot be 
checked while SYSLOG or SMTP is disabled. 

 

Figure 41 - System Warning – Event Selection Interface

 

The following table describes the labels for the System Warning screen. 

Label 

Description 

System Event

 

System Cold Start

 

Alert when the system restarts. 

Power Status 

Alert when there is a power up or down. 

SNMP Authentication 
Failure 

Alert when there is a SNMP authentication failure. 

iRing Topology Change 

Alert when the iRing topology changes.     

Port Event 
SYSLOG / SMTP event 

 

Disable

   

 

Link Up

   

 

Link Down

   

 

Link Up & Link Down

   

Apply 

Click “

Apply

” to activate the configurations. 

 

 

Содержание iES6 Series

Страница 1: ...et Switches iES6 iES6 S Series User s Manual Version 1 12 2020 iS5 Communications Inc 5895 Ambler Dr Mississauga Ontario L4W 5B7 Tel 1 905 670 0004 Fax 1 289 401 5206 Website www iS5Com com E mail sup...

Страница 2: ...period including shipping costs This warranty does not cover product modifications or repairs done by persons other than iS5 approved personnel and this warranty does not apply to products that are mi...

Страница 3: ...OVERVIEW 9 2 1 Front Panel 9 2 2 Rear 10 2 3 Bottom 10 2 4 Side 11 HARDWARE INSTALLATION 12 3 1 DIN Rail Mounting 12 3 2 Panel Mounting Option 13 3 3 Chassis Ground Connection 13 3 4 Power Connection...

Страница 4: ...0 5 1 6 3 iChain 31 5 1 6 4 iBridge 32 5 1 6 5 RSTP 33 RSTP Setting 34 RSTP Information 35 5 1 7 VLAN 37 5 1 7 1 VLAN Configuration Port Based 37 5 1 8 SNMP 37 5 1 8 1 SNMP Agent Setting 37 5 1 8 2 SN...

Страница 5: ...Set 52 6 4 Commands Set List RSTP command set 53 6 5 Commands Set List SNMP command set 55 6 6 Commands Set List TFTP command set 56 6 7 Commands Set List SYSLOG SMTP EVENT command set 56 6 8 Commands...

Страница 6: ...a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Ca...

Страница 7: ...s Supports Ring Linking Dual Homing over iRing and standard RSTP Supports SNMPv1 v2c v3 Port base VLAN Network Management Event notification by Email SNMP trap and Relay Output Web based Telnet Consol...

Страница 8: ...Default Setting Speed auto Duplex auto Flow control disable Ports 5 6 10 2 x 100Base F X SC or ST ports Optional Console 6 Use a RS232 to RJ45 cable to manage switch Reset 7 Push and hold the reset bu...

Страница 9: ...down fail Ports 1 to 6 10 100Base T X Fast Ethernet ports 8 LNK ACT Green On Port link up Blinking Data transmitted Full Duplex Amber On Port works under full duplex Ports 7 8 Optional 10 100Base T X...

Страница 10: ...nd ground lug of the iES6 and iES6 S switch Figure 3 10 Position Terminal Block and Ground Lug 2 4 Side On the full DIN version the holes circled in red are the side mounting holes for the Panel brack...

Страница 11: ...op of the switch back and hook the top of the DIN bracket onto the top of the DIN rail iES6 iES6 S Figure 5 DIN Rail Mounting 2 Push the bottom of the switch towards the DIN Rail until in clicks into...

Страница 12: ...Note To avoid damage to the unit use the 4 screws provided to install the panel mount brackets onto the switch iES6 iES6 S Figure 6 Panel Mounting 2 Use the holes in the brackets to secure the switch...

Страница 13: ...ther bare wire connections or crimped terminal lugs The use of 6 size ring lugs is recommended to ensure secure and reliable connections under severe shock or vibration The terminal block comes with a...

Страница 14: ...he safety ground terminal for AC Units or the ground bus for DC inputs Chassis ground connects to both power supply surge grounds via a removable jumper 5 PWR2 Positive Connected to the positive termi...

Страница 15: ...NO Failsafe relay normally open contact 9 RLY CM Failsafe relay common contact 10 N C No connection 3 5 Console Connection To manage the switch via console port connect the console cable provided wit...

Страница 16: ...Base T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ45 100Base T X Cat 5 100 ohm UTP UTP 100 m 328 ft RJ45 4 1 1 10Base T 100Base T X Pin Assignments With 10Base T 100Base T X cable pins 1 and 2 are used for...

Страница 17: ...transmit 7 Not used Not used 8 Not used Not used 4 2 Fiber Optics The iES6 Series are available with optional fiber ports The fiber optical ports are available in either Multimode or Singlemode and w...

Страница 18: ...ches can be managed via the console port on the front face using the RS 232 cable provided and a local PC The console cable pin assignment is as shown below PC pin out male assignment DB9 to RJ 45 Pin...

Страница 19: ...It is based on Java Applets with an aim at reducing network bandwidth consumption and enhances access speed in a viewing screen Note By default IE5 0 or later versions do not allow Java Applets to op...

Страница 20: ...n appears 4 Key in the username and password The default username and password are admin 5 Click Enter or click OK The change default password screen of the Web UI appears Figure 13 Change Default Pas...

Страница 21: ...tion The system information will display the configuration of Basic Setting Switch Setting page Enable Location Alert Click PWR1 and PWR2 LED s of the switch will start to flash Click and the LED s wi...

Страница 22: ...physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization 5 1 4 2 Admin Password Change web management login username and password for the manage...

Страница 23: ...dialog shows up to inform you that the DHCP client is enabled The current IP will be lost and you should see the new IP address on the DHCP server IP Address Assigns the IP address that the network is...

Страница 24: ...ng time is enabled you will need to configure the daylight saving time period UTC Time zone Sets the switch location time zone The following table lists the different location time zones for your refe...

Страница 25: ...n Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone...

Страница 26: ...he LLDP screen Label Description LLDP Protocol Enable or Disable LLDP function LLDP Interval The interval to resend LLDP by default is 30 seconds Apply Click Apply to activate the configurations Neigh...

Страница 27: ...ons Backup Click Backup to back up the configurations 5 1 4 7 Upgrade Firmware Upgrade Firmware allows you to update the firmware of the switch via the TFTP or from your local PC Before updating via t...

Страница 28: ...ts symmetrical and asymmetrical mode to avoid packet loss when congestion occurs Security Supports port security function When enabled the port will STOP learning the MAC address dynamically Apply Cli...

Страница 29: ...25 Fast Recovery Mode Interface Label Description Active Activate the fast recovery mode port Port can be configured as 5 priorities Only the port with highest priority will be the active port 1st Pr...

Страница 30: ...two rings Ring Linking Port Set a port as the Ring Linking port to link to the Ring Linking port of the switch in the other ring Ring Linking requires four switches to construct an active and a backup...

Страница 31: ...dge Port Only one Edge Port of the Edge Switch needs to be defined Other switches beside them just need to have iChain enabled State Status is Forwarding or Link down Figure 28 Typical iChain Applicat...

Страница 32: ...g Port Choose the port that will connect to the ring 2nd Ring Port Choose the port that will connect to the ring Figure 30 Typical iBridge Application 5 1 7 5 RSTP The Rapid Spanning TreeProtocol RSTP...

Страница 33: ...t If the value changes the switchmust be rebooted The value must be a multiple of 4096 according to the protocol standard Max Age 6 40 The number of seconds for a bridge to wait without receiving Span...

Страница 34: ...ed to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P is enabled False means P2P i...

Страница 35: ...ath to the other bridge from this transmitting bridge at the specified port A number 1 through 200000000 Port Priority Which ports should be blocked by priority in LAN A number 0 through 240 The value...

Страница 36: ...e same group of the port can be a normal transmission packet without restricting the types of packets Figure 33 VLAN Configuration Port Based VLAN Interface The following table describes the labels fo...

Страница 37: ...ires an authentication level of MD5 or DES to encrypt data to enhance data security SNMP V1 V2c Community SNMP Community should be set for SNMP V1 V2c Four 4 sets of Community String Privilege are sup...

Страница 38: ...erface The following table describes the labels for SNMP Trap Setting Label Description Server IP The server IP address to receive Trap Community Community for authentication Trap Version Trap Version...

Страница 39: ...iES6 Series User s Manual iS5 Communications Inc 40 5 1 9 3 SNMP SNMP V3 Setting Figure 36 SNMP Setting Figure 37 Access Table...

Страница 40: ...v3 access table 2 Context Prefix set up the context name 3 Group Name set up the group 4 Security Level select the access level 5 Context Match Rule select the context match rule 6 Read View Name set...

Страница 41: ...describes the labels for the SYSLOG Setting screen Label Description SYSLOG Mode Disable disable SYSLOG Client Only log to a local system Server Only log to a remote SYSLOG server Both log into both...

Страница 42: ...e describes the labels for the SMTP Setting screen Label Description E mail Alarm Enables and Disables the transmission system warning events by e mail SMTP Server Address The SMTP server IP address o...

Страница 43: ...led Figure 41 System Warning Event Selection Interface The following table describes the labels for the System Warning screen Label Description System Event System Cold Start Alert when the system res...

Страница 44: ...Interface 5 1 11 Save Configuration If any configuration has been changed Save Configuration should be clicked to save the current configuration data to the permanent flash memory If not saved the cu...

Страница 45: ...the labels for the Factory Default screen Label Description Keep current IP address setting When selected the IP address will be retained when the switch is reset to the factory default Keep current u...

Страница 46: ...e 9600 8 none 1 none Use an RJ45 to DB9 F cable to connect to the switch s console and to a local PC s COM port Follow the steps below to access the console via the RS 232 serial cable 1 Start Tara Te...

Страница 47: ...gure 48 Serial Port Setup 4 Press Enter on the keyboard for the Console login screen to appear Use the keyboard to enter the Console Username and Password which is same as the Web Browser password the...

Страница 48: ...rd same as the Web Browser password Note First login into device requires changes of the default password Follow the steps below to access the console via Telnet 1 Telnet to the IP address of the swit...

Страница 49: ...h Enter disable to exit The privileged command is advance mode Privileged this mode to Display advance function status save configures Global configuration Enter the configure command while in privile...

Страница 50: ...em location System Location G Set switch system location string switch config system location xxx system description System Description G Set switch system description string switch config system desc...

Страница 51: ...the duplex configuration command to specify the duplex mode of operation for Fast Ethernet switch config interface fastEthernet 2 switch config if duplex full speed 10 100 1000 auto I Use the speed c...

Страница 52: ...actual status switch config interface fastEthernet 2 switch config if show interface status show interface accounting I show interface statistic counter switch config interface fastEthernet 2 switch c...

Страница 53: ...d learning states last before the port begins forwarding switch config RSTP forward time 20 RSTP max age seconds G Configure RSTP max age parameter switch config RSTP max age 25 RSTP path cost 1to2000...

Страница 54: ...gent mode v1v2c v3 G Select the agent mode of SNMP switch config snmp agent mode v1v2c Snmp trap server IP address community Community string trap version v1 v2c G Configure SNMP trap server host info...

Страница 55: ...estore File name G Get configuration from TFTP server and need to specify the IP of TFTP server and the file name of image switch config tftp 192 168 10 66 restore file cfg TFTP IP address upgrade Fil...

Страница 56: ...anged event type switch config event ring topology change both event syslog Link UP Link Down Both I Set port event for system log switch config interface fastethernet 3 switch config if event syslog...

Страница 57: ...od 20060101 01 01 20060202 01 01 sntp daylight offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp i...

Страница 58: ...Port 2nd Ring Port G Configure 1st 2nd Ring Port switch config iring port 7 8 iRing ring linking port Coupling Port G Configure iRing linking Port switch config iring ring linking port 1 iRing homing...

Страница 59: ...undancy RSTP Fast Recovery and iRing LLDP Supports SNMPv1 v2 v3 Warnings Syslog and SMTP and Fault Alarm power and port failure SNTP for synchronizing of clocks over network Network Redundancy RSTP IE...