6
3.1 ANCHORAGE STRENGTH
The Horizontal Entry Arm is designed to be set up or installed, and used on a supporting surface
(anchorage) capable of providing sufficient anchorage strength to support all applied loads with an
acceptable margin of safety. The standards governing different situations specify various minimum
requirements depending on the application, the work being performed, and other factors.
However, at no time shall the anchorage provide any less than the greater of:
a 2:1 safety factor on the maximum arrest force (MAF) rating of any fall arrest system being
used,
a 4:1 safety factor on personnel working loads applied to the system,
a 4:1 safety factor on material handling loads applied to the system.
All installations MUST BE used under the supervision of a Qualified Person.
3.2 COMPATIBILITY OF CONNECTORS
Connectors used to connect components in the system must be compatible with each other to ensure
sufficient strength and eliminate the risk of accidental disengagement or rollout during use. Connectors
supplied with products designed, manufactured, and/or approved by
Irudek
Products Inc. will meet
applicable compatibility requirements for connectors. Any connectors not supplied by
Irudek
Products
Inc. MUST BE approved by a Qualified Person, and installed, inspected, and used according to the
respective manufacturer’s instructions.
3.3 FULL BODY HARNESS
Use only a full body harness designed, tested, and approved for fall arrest when connecting a person to
this winch. Body belts or straps do not provide adequate support to the body to prevent serious injury
or death in the event of a fall.
3.4 FALL PROTECTION
Activities involving working at heights require the use of equipment to protect the worker in the event
of a fall. Suitable fall protection must be provided as required by applicable local regulations when
using the
Side
Entry and related equipment.
3.5 CONFINED SPACE SAFETY
When the
Side
Entry is used as part of a system involving work in a confined space, always follow an
approved confined space safety plan meeting all local regulations.
Side
Entry
Operation and Maintenance Manual