3465&3485-mfc.ib.rev4.doc
page 12 of 22
17/10/2007
Operation
There are no operational controls for these modules. Setting up consists only of connecting the input and selected
output. Once this is done the front panel indicators should react and the output should present the correct format
signal.
Any change in signal will be indicated by the front panel LED’s and or alarm output as outlined below.
Front indicators:
Input loss alarm:
This LED lights when there is a loss of input signal or coding errors occur on the
input stream.
Sync loss alarm:
This LED lights for at least 300 ms when two or more MPEG-2 TS sync bytes are absent. The LED extinguishes
when five or more correct SYNC bytes are detected.
188 byte indicator:
This LED lights when a valid MPEG-2 TS stream containing 188 bytes between sync bytes is detected.
204 byte indicator:
This LED lights when a valid MPEG-2 TS stream containing 204 bytes between sync bytes is detected.
INPUT
SYNC
188
204