background image

 

DAA-4400 

I.R.T. Communications Pty Ltd | www.irtcommunications.com 

 

 

Page 5 of 14

 

Revision 02 

GENERAL DESCRIPTION 

 

 
The DAA-4400 is designed to provide a solution to most AES/EBU digital audio signal distribution requirements. 
 
The  DAA-4400  will  operate  at  AES  sample  rates  from  34  to  54 kHz and may be used with non-AES digital signals 
that have a net zero DC content. 
 
Whilst  analogue  VDA's  may  be  used  for  75 Ohm  AES  signals,  the  digital  circuitry  of  the  DAA-4400  offers  the 
advantage of restoring the signal rise and fall times and output level without the need to manually adjust gain and 
compensation controls. 
 
A choice of rear assembly is available for either 110 Ohm or 75 Ohm use. No changes are required to the main DA 
to convert between the two output types. The input includes both 110 Ohm and 75 Ohm input connectors and is 
link selectable on the main PCB. 
 
An optional SNMP (Simple Network Management Protocol) plug-in module is available for monitoring when used 
in an IRT frame fitted with SNMP capability. 
 
The DAA-4400 is designed to fit IRT’s standard 1RU and 3RU Eurocard frames and may be used alongside any other 
of IRT’s analogue or digital Eurocards. 

 

Standard features: 

 

8 outputs.

 

 

75 and 110 Ohm inputs.

 

 

Choice of 75 or 110 Ohm outputs by changing rear connector assembly.

 

 

Front panel monitoring output.

 

 

All inputs and outputs transformer coupled.

 

 

Digital circuit re-shapes output and restores level.

 

 

No cable compensation adjustments required.

 

 

Optional plug-in SNMP monitoring module.

 

BLOCK DIAGRAM DAA-4400 SIGNAL PATH 

75 Ohm 

 

110 Ohm

 

8 x 

75 Ohm 

or 

110 Ohm 

SNMP 

Содержание DAA-4400

Страница 1: ...DAA 4400 I R T Communications Pty Ltd www irtcommunications com Revision 02 AES EBU Digital Audio Distribution Amplifier User Manual...

Страница 2: ...TION AMPLIFIER Revision History Revision Date By Change Description Applicable to 00 15 03 2005 AL Original Issue Serial numbers 0406001 01 29 01 2010 AL Front panel layout changed and AES sample rate...

Страница 3: ...y 2 Operational Safety 4 General Description 5 Technical Specifications 6 Configuration 7 Installation 8 Signal Connections 8 SMU 4000 Installation 9 Figure 1 SMU 4000 module 9 Front and Rear Layouts...

Страница 4: ...conditions dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside eq...

Страница 5: ...changes are required to the main DA to convert between the two output types The input includes both 110 Ohm and 75 Ohm input connectors and is link selectable on the main PCB An optional SNMP Simple...

Страница 6: ...ements Voltage 28 Vac CT 14 0 14 or 16 Vdc Power consumption 4 VA Connectors Balanced Phoenix 3 terminal plug in blocks Unbalanced BNC Other Temperature range 0 50 C ambient Mechanical Suitable for mo...

Страница 7: ...75 unbalanced BNC regardless of rear assembly chosen On board link settings both SW1 and SW2 need to be set for either 110 balanced terminating or 75 unbalanced terminating depending on the input con...

Страница 8: ...at the frame is connected to earth for safety reasons See frame manual for details Signal earth For safety reasons a connection is made between signal earth and chassis earth No attempt should be made...

Страница 9: ...f the SMU 4000 line up with the three sets of multipin sockets on the main PCB module Align all pins and then gently press the SMU 4000 all the way down into place If the SMU 4000 is not already progr...

Страница 10: ...R T Communications Pty Ltd www irtcommunications com Page 10 of 14 Revision 02 Front rear panel connector diagrams ZAA 4400 Rear Assembly Un Balanced O P s Optional ZAA 4401 Rear Assembly Balanced O P...

Страница 11: ...n and translates that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control commands...

Страница 12: ...T modules that are SNMP compatible may need an optional plug in SNMP module with a program relevant to the module that it is plugged into Depending on the module besides the module identification para...

Страница 13: ...since its last power on or reset in Days Hours Minutes and Seconds sysName A 16 character writable system name Default set name DDA 4010 irt4400Alarms An indication of the current state of the alarm s...

Страница 14: ...e Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be service...

Отзывы: