CLEAR A PROGRAM
Note: The Clear Program process restores the default program. All scheduled
watering days, start times and valve run times are eliminated. Water Budget becomes
100%.
1. Set the Function Switch to Set Program
.
2 Turn the Dial to Spl Func. When the display shows “CLR”, the controller is ready to
clear the program.
3. Set the Program Selector to A, B, or C (the program you want to clear).
4. Press the + Button. “OK?” is displayed.
5. Press the + Button again. “CLR” is displayed and the program is reset.
6. To clear another program, repeat steps 3, 4 & 5.
7. Turn the Dial to another position when you have completed the Clear Program
process.
SELECT LANGUAGE
1. Set the Function Switch to Set Program
.
2. Turn the Dial to Spl Func.
3. Press the Next
Button.
4. Press the +/- Buttons until the desired language appears. The display shows the
abbreviation of either the default or selected language, ENG = English,
ESP = Spanish, FRA = French, DEU = German, ITA = Italian. English is default.
WATER BUDGET adjusts all watering times in a selected program by a fixed
percentage, from 0 - 200% in 10% increments. Each program can have a different
Water Budget.
1. Set the Function Switch to Set Program
.
2. Set the Program Selector to the program you wish to budget, A, B, or C.
3. Turn the Dial to %.
4. Press the +/- Buttons to select the desired Water Budget %.
Special Features
16
Water Budget