background image

1 of 10

Thank you for purchasing the Ironwood 5kW woodburning stove.  Follow these simple instructions and 
guidelines to ensure you get the best and safest operation from your Ironwood stove.

General

To ensure the safe installation of this appliance it must be 
installed by a Hetas registered engineer or approved by 
your local building control officer. 

•  Only burn approved fuels

•   Regular maintenance and chimney sweeping is required 

(see care & maintenance)

•   Do not make any unauthorised modifications or changes 

to the appliance.

•   Do not place combustible materials such as fuel close or 

in close proximity to the appliance

•   Furniture should be at least 1 metre in distance from the 

appliance

Technical information

Dimensions

Nominal Heat Output

5 kW

Efficiency

80.3%

Fuel

Wood Only

Model

IW W5kW

Weight

106Kg

Width

550mm

Depth

360mm

Height

645mm

Spigot internal dimension

155mm

Distance from rear to centre of spigot

135mm

Distance to combustibles

Side 300mm 
Rear 600mm

Intermittent operation only

550

645

520

360

135

Dimensions mm

5kW Wide Woodburning Stove 

Содержание IW W5kW

Страница 1: ...5kW Wide Woodburning Stove User Instruction Manual Issued June 2021 Document No IW5WM01...

Страница 2: ...ired see care maintenance Do not make any unauthorised modifications or changes to the appliance Do not place combustible materials such as fuel close or in close proximity to the appliance Furniture...

Страница 3: ...ste wood eg old furniture pallets or fence panels or household rubbish Treated waste wood and household rubbish can emit harmful fumes and toxic pollutants into your home when burnt Do not use liquid...

Страница 4: ...ring and damage the appliance STEP 2 Moving towards optimum temperature When an optimum temperature of between 150 and 250 Celsius on the outer body of the stove is reached push the slider again furth...

Страница 5: ...e metal container Do not place hot ash in a container made from plastic or combustible material Ash can remain hot for a long period of time after use ensure sufficient time has lapsed before removing...

Страница 6: ...f the pipe to allow a tight fit A mechanical fixing such as a self tapping screw or rivet is required to secure the pipe into position While this connection is made we advise to lift the stove top in...

Страница 7: ...on the requirements of the Clean Air Act can be found here at https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designatio...

Страница 8: ...pply of air to maintain good combustion Extractor fans or cooker hoods must not be placed in the same room as this can cause fumes to emit into the room Care Maintenance Annual service Before the star...

Страница 9: ...front opening of the stove To remove the rear firebrick the grate is to be moved vertically and then taken out of the front opening of the fire Only use replacement parts supplied or recommended by I...

Страница 10: ...lacement rope Wait approximately 12 hours for the rope adhesive to set before using the stove Glass dimensions 407mm x 310mm Rope diameter 10mm soft rope Seasonal use Over the summer months when the s...

Страница 11: ...e and over heating High flue draft Consult your installer who may advise use of an anti downdraft cowl Excessive fuel use Fuel too dry Do not use constructional timber or pallet wood Excess air into f...

Страница 12: ...Tel 01446 771567 www ironwoodstoves co uk...