Page of 18
13
.
b. Remove the carbon brushes from the housing.
Keep track of which orientation the old
carbon brushes were in to prevent needless wear if they will be reinstalled.
.
c. If either carbon brush is worn down by more than 1/2, replace them both.
.
d. To clean old carbon brushes before reusing them, rub the contact areas with a pencil eraser.
.
e. Reinsert the old carbon brushes in the same orientation to reduce wear.
.
f. When installing, make sure the carbon portions of the brushes contact the motor armature,
and that the springs face away from the motor. Also, make sure the springs operate freely.
.
g. Replace the Carbon Brush Covers. Do not overtighten.
.
Note:
New carbon brushes tend to spark when first used until they wear and conform to the motor’s
armature.
•
AFTER USE,
wipe external surfaces of the tool with clean cloth.
•
Before remounting the Saw Blade, remove all sawdust that has accumulated around the Safety
Guard and Blade Guard Frame.
•
Regularly inspect and tighten all mounting screws and knobs.
•
Keep Saw Blade clean and sharp. Sharp blades minimize stalling and kickback.
•
Keep guards in good working order.
•
Keep motor air vent clean of dust and debris. Vacuum periodically.
•
If the tool is not operating normally, making unusual noises, or appears defective, stop using it
immediately and get it repaired.
•
Clean tool with a damp cloth and light detergent. Do not use solvents as they can damage and
crack the housing.
•
For blade changing instructions see Tool Set Up on page 10.
•
WARNING!
If the supply cord of this power tool is damaged, only a qualified
service technician must replace it.