Page of 19
8
ON/OFF Switch
In the “OFF” position no power is being supplied to the electrode holder. In the “ON” position
power is supplied to the main transformer and control circuit.
Indicator Lights
There are two indicator lights: 1) Power and 2) Thermal Overload. When the machine is turned on,
the power indicator will be on. When the thermal overload indicator is on, it indicates the machine
has exceeded the duty cycle and the internal temperature is too high. The machine automatically
turn off welding output but the fan will remain on to cool down the internal components. When the
internal temperature had decreased, the machine will automatically turn welding output back on.
Ground Cable and Clamp
The ground cable and clamp are attached to the work piece to complete the circuit allowing the flow
of current needed to weld.
Welding Cable and Electrode Holder
One end of the cable is connected to the output connector of the welder. The electrode is held in the
electrode holder for welding.
Current Adjustment
Current adjustment is on the front panel of the machine. It has infinite current output adjustment
from 60 to 200 Amps as indicated on the amperage indicator window on the top of the machine.
Power Cord
The power cord connects the welder to the 230 volt power supply. Plug the 50 amp NEMA 6-50P
plug into a NEMA 6-50R receptacle to supply power to the welder.
ASSEMBLY
1. Tools required for assembly: Open-end wrenches 8 and 10mm.
2. 1. Lay the machine side panel on a flat surface. Install the metal bracket support on the bottom
using two sets of screws and washers from the hardware bag. See following image.
Содержание 45432
Страница 17: ...Page of 19 17 DIAGRAM PARTS LIST ...