IronStrike Ravenna RDV33 IPI Скачать руководство пользователя страница 34

34

REPLACEMENT PARTS - RDV33/40 IPI, RDV33/40 TCC

Item #

Cat. No.

Description

1

H5839

Log Set Support Panel

2

H8502

Left Face Hanging Bracket with Mounting Screws

3

H5748

Refractory Panel Retaining Bracket Set, 
1" Thickness

4

H8492

Flue Collar Kit

5

H5723

Air Intake Kit

6

H8501

Right Face Hanging Bracket with Mounting Screws

7

H5727

Leveling Leg Kit - 2 legs with Screws 

8

H8500

Door Latch Assembly

9

H8503

RDV Blower Mounting Assembly

10

H8499

Firebox Door Assembly with Glass  

11

H6010

Burner Assembly

12

H8504

RDV IPI Control Panel

13

H8505

RDV TCC Control Panel

14

H8482

Heat Shield, Fan Control Module - For TCC Models 
Only

15

H8483

Blower Snap Switch, 160°-20°F

16

H3077

Power Cord, C13 End

17

H8493

RDV Blower with Mounting Screws

18

H8494

Power Inlet/Outlet Junction Box Assy

19

H8006

AC Power Adaptor

20

H8495

4 AA Battery Holder Assy (Batteries not included)

21

J7906

Ignition Control Board

22

H7277

Remote Receiver, GT/GTMF, Replacement - For 
Models with Optional GT Remote Control Kit 
Installed or TCC Models Only

---

H8519

Remote Control, GT, Replacement - For Models with 
Optional GT Remote Control Kit Installed Only

---

H7275

Remote Control, GTMF, Replacement - For TCC 
Models Only

23

H5744

On/Off Switch, Burner and Pilot Mode

24

H5655

Blower Speed Control (Rheostat)

25

H7274

Fan Control Module - For TCC Models Only

---

H8484

Pilot Ground Wire

---

H8485

RDV IPI Blower Wiring Harness

---

H8486

Wire Extension Harness for Surround Mounted On/
Off Switch  

---

H8487

Ignition Control Board Wiring Harness, 19"

---

H8488

GT Remote Receiver Wiring Harness, 18" - For 
Models with Optional GT Remote Control Kit 
Installed Only

---

H8489

Ignition Control Board and GTMF Remote Receiver 
Wiring Harness 18" - For TCC Models Only

---

H8496

RDV TCC Blower Wiring Harness

26

H8506

Cassette Assembly NG 40,000 BTU (if LP, also 
requires H8457  Conversion Kit) - For Models RDV 
IPI with Manual Hi/Lo Regulator

26

H8507

Cassette Assembly NG 40,000 BTU (if LP, also 
requires  H8459  Conversion Kit) - For Models RDV 
TCC with Auto Hi/Lo Regulator

27

H8490

3/8" NPT Pipe Nipple, 8" 

28

H8498

Air Shutter Tube Assy

29

H5924

Orifice, Main Burner #36 NG 33,000 BTU  

29

H5925

Orifice, Main Burner #51 LP 33,000 BTU  

Item #

Cat. No.

Description

29

H5929

Orifice, Main Burner #49 LP 40,000 BTU  

29

H5963

Orifice, Main Burner 1/8" NG 40,000 BTU  

30

H8481

Pilot Shield

31

H8491

Pilot Assembly Convertible, NG or LP  

32

H8508

Gas Control Valve, Manual Hi/Lo Regulator, NG  (if 
LP, also requires H8457  LP Regulator)

32

H8509

Gas Control Valve, TCC Auto Hi/Lo Regulator, NG  
(if LP, also requires H8459  LP Regulator)

---

H8458

Gas Conversion Kit, TCC Auto Hi/Lo Regulator, LP 
to NG

---

H8459

Gas Conversion Kit, TCC Auto Hi/Lo Regulator, NG 
to LP

---

H8456

Gas Conversion Kit, Manual Hi/Lo Regulator, LP 
to NG

---

H8457

Gas Conversion Kit, Manual Hi/Lo Regulator, NG 
to LP

---

H3080

Control Valve Knob Extension, Manual Hi/Lo - SIT

33

H5752

Wire Grommet

34

H8497

Hook and Loop Dot Kit - 4 sets

36

H8651

TCC Power Adaptor Box Assembly

37

H8650

Convection Air Deflector

38

J7510

Barrier (on Contemporary facade)

39

J7511

Barrier (on Pillar Cast facade)

---

H5858

High Detail Log Set  

---

H5864

Bag of Glowing Embers - Rockwool  

---

H5863

Bag of Embers - Volcanic Stone

---

H5989

Hardware Package  

---

H8518

Gasket Kit

---

H8159

Touch-Up Paint, Metallic Black (12 oz aerosol)

Contact an IHP dealer to obtain any of these parts. Please contact IHP 

for the phone number of your nearest IHP dealer.

       WARNING 

Never use substitute materials. Use of non-approved 

parts can result in poor performance and safety haz-

ards.

       WARNING 

Failure to position the parts in accordance with these 

diagrams or failure to use only parts specifically 

approved with this appliance may result in property 

damage or personal injury.

       AVERTISSEMENT 

Risque de dommages ou de blessures si les pièces 

ne sont pas installées conformément à ces schémas 

et ou si des pièces autres que celles spécifiquement 

approuvées avec cet appareil sont utilisées.

Содержание Ravenna RDV33 IPI

Страница 1: ...ly call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a...

Страница 2: ...O CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact ac...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...t Leveling 14 Fan Control Module Switch RDV 33 40 TCC models only 15 Installation 15 21 Venting Installation 15 Zero Clearance Fireplace Installation 17 USING THIS MANUAL Please read and carefully fol...

Страница 5: ...ls viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une ba...

Страница 6: ...ing es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefa...

Страница 7: ...pareil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour limi...

Страница 8: ...se or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the...

Страница 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Страница 10: ...ural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Require...

Страница 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CS...

Страница 12: ...rmation This appliance comes from the factory equipped to burn natural gas at a specified elevation Only IHP conversion kits can be used to convert from NG to LP or LP to NG Contact your IHP dealer fo...

Страница 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Страница 14: ...screws Repeat these steps for each adjusting leg Facing and Mantel Clearances Please note that the RDV33 IPI TCC mantel clearances are 4 less than the RDV40 IPI TCC mantel clearances as shown in Figu...

Страница 15: ...tructions for installation and vent termination These appliances are approved for use with the following vent kits Amerivent Flex Liner 3 X 35 3AFL 35 Adaptor w Flashing 4DCAT33 Termination Cap 4DVC S...

Страница 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Страница 17: ...000 BTU Natural Gas Input To convert input from 40 000 BTU s to 33 000 BTU s Assuming the front door is already removed 1 Remove the log rack Use a 5 32 allen wrench by removing two screws on the fron...

Страница 18: ...oundpanelsinfrontoftheholesonthesurroundbrackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss s...

Страница 19: ...e Figure 15 The panel has keyhole slots where it mounts to the base Loosen the two nuts securing the panel using 3 8 wrench Carefully move out the panel far enough to access the back Do not pull the p...

Страница 20: ...ak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the residen...

Страница 21: ...r will result in bigger flames and more color To adjust the air shutter insert a regular screwdriver into the slide adjustment and slide it side to side see Figures 19a and 19b CAUTION The air shutter...

Страница 22: ...r 9 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn the burner ON OFF switch...

Страница 23: ...e SIT Proflame Stepper Electronic Pilot Assembly Electronic Pilot Assembly Unit Mounted Controls Unit Mounted Controls Intermittent Standing Pilot Mode On Auto Pilot Mode Switch Thisappliancecanbeswit...

Страница 24: ...s to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries alread...

Страница 25: ...d off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position see...

Страница 26: ...r proper main burner operation at both high and low flame OPERATION RDV33 40 TCC Models Only No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No S...

Страница 27: ...MOTE RECEIVER BLOWER SPEED CONTROL PILOT ON AUTO SWITCH AC DC ADAPTER POWER OUTLET BOX 6 WHT 5 BLUE WHT BLK WHT BLK BLK BLK 4 GRN GRN 8 GRN 3 GRAY 14 RED 9 GRN 2 RED 1 RED 3 BLK 2 BLK 1 RED PILOT ROOM...

Страница 28: ...10 ORG 13 BLK 12 BRN 14 RED 4 PUR WHT BLK BLK WHT 4 GRN 8 GRN 2 BLK 3 BLK 1 RED 9 WHT 3 GRAY 2 RED GRN 1 2 3 4 1 Figure 28C Electronic Control Schematic Models RDV33 40 TCC NOTE SWITCH CONDITIONS GIVE...

Страница 29: ...n those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified age...

Страница 30: ...doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while reinstalling the glass door frame The glass door s o...

Страница 31: ...Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass door log set and firebox liner pan...

Страница 32: ...art No J7510 2 Place sight obstructers back over the threaded studs taking note that the upper and lower horizontal bar ends line up with grooves in sight obstructers see Detail A in Figure 33 3 Reins...

Страница 33: ...llation on Pages 17 and 18 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed...

Страница 34: ...with Manual Hi Lo Regulator 26 H8507 Cassette Assembly NG 40 000 BTU if LP also requires H8459 Conversion Kit For Models RDV TCC with Auto Hi Lo Regulator 27 H8490 3 8 NPT Pipe Nipple 8 28 H8498 Air S...

Страница 35: ...STRATIONS ARE NOT TO SCALE REPLACEMENT PARTS RDV33 40 IPI RDV33 40 TCC 14 36 25 33 34 21 22 23 13 32 31 30 29 28 1 27 26 2 3 4 5 15 6 7 16 37 8 17 9 10 11 20 19 33 21 34 22 23 12 24 18 38 Facade Cast...

Страница 36: ...ruction sheets included in kits Orifice Kits Main Burner 33 000 BTU converts from standard 40 000 BTU input to optional 33 000 BTU input Cat No Description H5924 Orifice Main Burner 36 Natural Gas 33...

Страница 37: ...29 x 48 Black Trim Includes black trim x x x H8556 RDV DBV FP3341 D 33 x 41 Black Trim Includes black trim x x x H8557 RDV DBV FP3348 D 33 x 48 Black Trim Includes black trim x x x 75362 RDV DBV FP294...

Страница 38: ...wing below Cat No Model Description 75156 RDV DBV PCFP3044 TOP Top Box 1 of 2 75157 RDV DBV PCFP3044 SIDES Sides Box 2 of 2 Pillar Cast Face Kits u Note 3 boxes to complete face 37 5 8 W x 23 3 4 H F2...

Страница 39: ...1 8 49 36 51 UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777...

Страница 40: ...PED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUS...

Страница 41: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 42: ...42 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Страница 43: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions prov...

Страница 44: ...s should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model numb...

Отзывы: