Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900205-00, Rev. B  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

IronStrike

®

 Brand Wood Burning Stove and Insert

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your IronStrike

®

 Brand Wood Burning Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime 

Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 

Limited Lifetime Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If 

repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will 

also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS 

AND LIMITATIONS to this Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this Limited Lifetime Warranty. The following do not carry a Limited Lifetime Warranty but are warranted as follows:

Cast Iron Heat Exchanger

 – Replacement for five years from the date of installation

Cast iron parts

 – Replacement for one year from the date of installation

Catalyst 

– Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components

 – Repair or replacement for one year from date of installation

Gaskets

 – Replacement for one year from the date of installation.

Gold & nickel plating

 – Replacement for two years from date of installation. Excludes tarnishing

Refractory & screens

 – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes

 – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products 

using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves, inserts and high efficiency EPA 

fireplaces are approved for burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions 

provided with the Product; (d) damages, repairs or  inefficiency resulting from faulty installation or application of the Product.
Coverage of this Limited Lifetime Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.
IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which 

may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate 

chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with Security 

Chimneys International, Ltd. chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this Limited Lifetime Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 

Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a contrac-

tor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ 

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.IRONSTRIKE.US.COM.

Содержание Grandview GV230GL

Страница 1: ...e la pi ce 900936 01 This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and operation manual before instal...

Страница 2: ...uirements 5 Negative Pressure Warning 5 Clearances 6 8 Clearances to Combustibles GV230GL 7 Alcove Floor Protection GV230GL 8 Specifications 9 Typical Installation Figures 10 Chimney Installation 11 M...

Страница 3: ...spectyourchimneyatleastonceamonthduringtheburn Safety and General ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney s...

Страница 4: ...e Inwellinsulatedandweathertighthomes itmaybedifficulttoestablish a good draft up your chimney The poor draft is caused by a shortage of air in the house In this situation an Outside Air Kit may need...

Страница 5: ...mon household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combustion process...

Страница 6: ...fore installing Residential chimney systems must be from the same brands as listed for mobile homes but connector pipe may be double wall single wall or single wall with shield as listed This applianc...

Страница 7: ...4 3 4 15 38 5 8 45 33 16 0 84 57 1 2 10 254 162 533 292 200 121 381 981 1143 838 406 0 2134 1461 N A Double Wall Alcove Vertical Vent 13 9 3 8 22 1 2 13 8 N A N A 38 5 8 48 33 16 0 72 N A N A 330 238...

Страница 8: ...hickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 47 TM inches 35 x 50 47 312 inches 745 x 50 Answer The minimum required thickness of the M...

Страница 9: ...on instructions Productdesigns materials dimensions specifica tions colors and prices are subject to change or discontinuance without notice Approved for residential manufactured home GV230GL only and...

Страница 10: ...Stainless Steel Liner Figure 9 Typical Installation Figure 10 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single...

Страница 11: ...Mobile home installations require a spark arrestor at the chimney termination All mobile home installations require an outside air kit see Page 30 for ordering information and the stove must be secure...

Страница 12: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Страница 13: ...urface below that the stove in located on LEG INSTALLATION Figure 14 PEDESTAL INSTALLATION Residential and Mobile Homes Tieing down and grounding are required only in mobile homes Open all cartons if...

Страница 14: ...TURED HOME FLOOR THE STOVE MUST BE ATTACHED TO THE FLOOR AT NO LESS THAN TWO POINTS Pedestal Locate the two holes on the back of the pedestal Figure 15 Secure the pedestal to the floor using two field...

Страница 15: ...ust not be installed more than ten 10 feet 3050 mm above the base of the stove C The fresh air must come from outside the house The air intake must not draw air from the attic from the basement or gar...

Страница 16: ...Installed Figure 24 Baffle Boards Letter A Brick Are Full Size 9 229mm Long x 4 1 2 114mm Wide x 1 5 16 33mm Thick Back Baffle Board Front and Rear Baffle Boards 2 each Front Baffle Board 1 Install b...

Страница 17: ...ward and slide left to release from right side Remove tube from stove Repeat process for secondary tube number two Gently lift top baffle board and slide forward tilt left side up and left slightly al...

Страница 18: ...it may be necessary to rotate timer engagement link slightly to properly mount timer and align with vertical timer link do not rotate more than 180 degrees Toreattachtimerengagementlink liftupwardslig...

Страница 19: ...tly every 5 10 minutes to keep the gasket from adhering to the curing paint Ventilate the house well during these first firings as the paint gives off carbon dioxide and unpleasantodors Itisrecommende...

Страница 20: ...of draft present 5 When operating any wood burning appliance it is important to become familiar with how the damper control affects heat output andtheoveralltemperatureoftheappliance Astovethermometer...

Страница 21: ...ng and ash removal DO NOT OVERFIRE THIS HEATER Attempts to achieve heat output rates that exceed heater design specifica tions can result in permanent damage to the heater Figure 32 Figure 33 OK What...

Страница 22: ...ove or insert enhances heat transfer thus allowing more time for heat to be transferred into your home To do this be sure to thoroughly preheat your stove and then reduce the amount of primary air by...

Страница 23: ...uild up to warm the air being moved by the blower before the blower is turned on Likewise when the stove cools off the blower is turned off to prevent circulating cool air Depending on the size and in...

Страница 24: ...as shown Arrows indicate screw locations CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasiveclean...

Страница 25: ...ed in the closed container until all the cinders have thoroughly cooled Ashes can ignite up to 72 hours after removal from the appliance Establish a routine for the fuel wood burner and firing techniq...

Страница 26: ...ng department for requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and...

Страница 27: ...s 3 See Poor Draft section above and Cleaning Glass on Page 24 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN 2 Check the chimney...

Страница 28: ...andRake H5564 15 RemovableAshPlug H8381 BLOWERPARTS Item Description GV230GL 16 Blower Snap Switch H8374 17 Blower Blade H8375 18 Blower Cover H8376 19 Speed Control High Temperature H5742 20 Blower R...

Страница 29: ...T PARTS MODELS GRANDVIEW 230GL 32 15 24 28 14 2 1 3 5 4 12 10 11 8 7 27 24 6 9 30 17 19 20 16 21 18 22 13 34 31 33 37 23 29 36 35 Planning Installation Safety and General Installation Operation Mainte...

Страница 30: ...H7665 14 W LEGF LBRKT Leg Tie Down Kit Olympic Legs Mobile Homes H5308 W LLK Leg Leveling Bolt Kit H8407 PEDESTAL REQUIRED Item Model Description GV230GL 1 PED GV GL GV GL Pedestal Black F4033 OR LEGS...

Страница 31: ...on must be a non combustible hearth floor protector with a minimum thickness of 3 8 9 5mm extending beneath the heater and to the front sides and rear as indicated NOTICE All mobile home installations...

Страница 32: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Страница 33: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Страница 34: ...ys give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation da...