background image

31

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900205-00, Rev. B  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

IronStrike

®

 Brand Wood Burning Stove and Insert

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your IronStrike

®

 Brand Wood Burning Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime 

Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 

Limited Lifetime Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If 

repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will 

also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS 

AND LIMITATIONS to this Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this Limited Lifetime Warranty. The following do not carry a Limited Lifetime Warranty but are warranted as follows:

Cast Iron Heat Exchanger – Replacement for five years from the date of installation

Cast iron parts – Replacement for one year from the date of installation

Catalyst – Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components – Repair or replacement for one year from date of installation

Gaskets – Replacement for one year from the date of installation.

Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing

Refractory & screens – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products 

using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves, inserts and high efficiency EPA 

fireplaces are approved for burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions 

provided with the Product; (d) damages, repairs or  inefficiency resulting from faulty installation or application of the Product.
Coverage of this Limited Lifetime Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.
IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which 

may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate 

chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with Security 

Chimneys International, Ltd. chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this Limited Lifetime Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.
LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 

Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a contrac-

tor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ 

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.IRONSTRIKE.US.COM.

Содержание COUNTRY Performer S210

Страница 1: ...en faire la demande Numéro de la pièce 900132 00 This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and operation manual beforeinstallingandusingyourwoodstove Failuretofollowtheseinstructions could result in property damage bodily injury or even death Contact your local building or fire officials to obtai...

Страница 2: ...essure Warning 5 Creosote 5 Disposal of Ashes 5 Fuel 6 Paint Curing 6 Burn In Period 6 Clearances to Combustibles 7 8 Floor Protection 7 Reduced Clearances 7 Alcove Clearances 7 Chimney and Connector 7 Components Required for Installation 7 Installation Clearances 8 Typical Installation Figures 9 Chimney Installation 10 Manufactured mobile Home Installations 10 Chimney Wall Pass Through Requiremen...

Страница 3: ...ng season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a hot fire If large ac cumulationsareoccurring reviewyourburningprocedures 14 Ifacreosotefireshoulddevelop thefiredepartmentshould be called immediately and then attempts should be made to control the ...

Страница 4: ...g system are too restrictive see Chimney Guide lines Inadequate draft will cause the appliance to leak smoke into the room through the stove and the chimney connector joints performance problems as well as be a safety hazard A draft test should read greater than 04 W C inches water column and less than 08 W C As per NFPA 211 standard see paragraph below the installer must take into account all var...

Страница 5: ...place insert with a small metal shovel Ashes should be placed in a steel container with a tight fitting lid and moved outdoors immediately Other waste shall not be placed in this container The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherw...

Страница 6: ...E THE AMOUNT OF AIR ENTERING THE STOVE IMMEDIATELY BURN IN PERIOD PAINT CURING Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 23 for a list of prohibited fuels Failure to burn proper fuels only will void the certification and the warranty of the appliance Dry seasoned wood is that which has been cut split and allowed to dry under a covered area where air is free to flow and circu...

Страница 7: ...s listed above This appliance may be vented into a code approved masonry chimney with flue liner WARNING Chimney connector must be in good condition and kept clean Do not install damaged parts All of the stove connector pipe used must be of the same brand The chimney that the stove pipe transitions into may be a different brand Other than the transition of the stove pipe into the chimney do Not mi...

Страница 8: ...AN 450mm USA 0 CAN 200mm Footnotes 1 These dimensions to the stove body are forreferenceonly Actualdistancesshould be measured from the stove s flue collar 2 Minimum noncombustible hearth pad dimensions 3 Shield shall be attached to the rear of the stovepipewitha1 airspaceandmustrun from the top of the stove to the ceiling 4 Not applicable to alcove installations 5 In corner applications when inst...

Страница 9: ...gure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not pass through attics closets walls or ceilings It is used to connect this appliance to a factory built or masonry chimney INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS INSTALL VENTING SYS...

Страница 10: ...rmination All mobile home installa tions require an outside air kit see Page 29 for ordering information and the stove must be secured to the floor and grounded to the mobile home chassis Install Outside Air Kits per instructions on Page 12 INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS Fasten stove pipe to flue collar using 3 sheet metal screws SecureStove to floor Grounded to Steel C...

Страница 11: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimney section supported on both sides with sheet steel supports of minimum 24 gauge 0 024 in 0 61 mm thickness Supports shall be securely fastened to wall surfaces on all sides and shallbesizedtofitandho...

Страница 12: ...pt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves during installation in case of sharp edges on the stove Leg Installation 1 Carefully place stove on it s back Be careful not to scratch the stove use a piece of cardboard or carpet to protect the back of the stove 2 Mount all four legs as shown in Figure...

Страница 13: ... in that leg as well 9 Install bricks and baffle as per instructions on Pages 15 and 16 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blankets can be adjusted into place through the flue collar 10 If installed into a mobile home the stove shall be grounded to the mobile home chassis with a 8 AGW copper wire or equivalent 11 For residential...

Страница 14: ...e chassis with a 8 AGW copper wire or equivalent 11 Install bricks as per instructions on Pages 15 and 16 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blankets can be adjusted into place from the flue outlet 12 Install chimney as per manufacturer s instructions For ash drawer pedestal see instructions included with pedestal Residential an...

Страница 15: ... dimensions on next page to be sure the correct bricks are installed in the correct location 1 Install bricks 1 26 in the numbered sequence shown in Figure 14 on Page 16 NOTE Beforeinstallingyourbaffleboardsmakesurethestainless steel tube support and front and rear tube hangers are centered side to side and that the front and rear hangers are hooked onto the stainless steel pins protruding from th...

Страница 16: ...ly smaller to adjust for steel and firebrick tolerances beyond our control Be sure to measure and mark bricks with their numbers when removing WARNING IF THE BRICKS ARE NOT INSTALLED EXACTLY AS SHOWN BELOW THEY COULD FALL OUT OF PLACE DURING REFUELING OR BURNING OF THE STOVE CAUSING SERIOUS INJURY Firebox Brick Layout as Viewed from the Front Figure 14 Bricks 6 and 10 fit up against the back of th...

Страница 17: ...rmometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 minutes or so until you become more familiar with your appliance Close the damper all the way down if you begin to reach 500 degrees as this is a sign...

Страница 18: ...hot enough to effectively heat the air moved by the blower If the air coming from the blower feels cool one should either decrease the blower speed or stoke the fire to build up more heat NOTE Turn blower off before opening the door to load the fuel BLOWER OPERATION Figure 19 Blower Controls Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation The blower can be operated ma...

Страница 19: ... to load This indicates the stove is too hot to load for a long burn Also do not load wood for a long burn on a deep bed of hot coals Try stirring the coals a few minutes before loading the stove for a low burn to allow some of the unburned coals time to burn ACHIEVING CLEAN LONG BURNS It is important to know that for high combustion efficient clean burns you will need to have sufficient temperatu...

Страница 20: ...spected at least once a year by a qualified service technician to ensure gaskets air tubes baffles and venting are in good repair to ensure proper performance Have degraded items replaced by a qualified service technician PLATED ACCESSORIES Clean only with household type glass cleaner and a very soft cotton cloth Other products may damage plated finish paint and gaskets BAFFLE BLANKET Your baffle ...

Страница 21: ...ild up Higher burns less build up Keep freshly loaded wood away from the glass After reloading allow all the wood to catch flame before dampering down the appliance GLASS REPLACEMENT INSTRUCTIONS Step 1 Remove Door Assembly Open door to remove E clip from the upper hinge pin Remove upper hinge pin by pulling up while holding the op posite side of the door Lift door out of the lower hinge pin and p...

Страница 22: ...17 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote see Chimney and Creosote sections on Pages 5 and 7 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed fur...

Страница 23: ... for requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the infl...

Страница 24: ...astener Kit 23 71115 Bottom Heatshield S210A 24 H5662 Cascade Olympic Leg Kit Outside Air Plenum Box FSB BLOWER PARTS 25 H8062 FSB700 Blower Only Assembly w blower wiring harness 26 H5658 Fan Blade FSB700 27 H5657 Fan Cage FSB700 28 H8063 FSB700 Blower Only Wire Harness 29 H8064 Snap Switch w gasket and screws 30 H5742 Speed Control High Temperature FSB700 31 H8065 Control Panel Assembly w Snap Sw...

Страница 25: ...25 REPLACEMENT PARTS MODEL S210A 34 47 48 46 33 35 41 41 45 39 39 43 39 39 39 39 43 39 39 36 40 40 40 40 44 37 38 39 39 39 42 39 39 39 42 ...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Door Parts Blower Parts 7 1 2 3 4 5 6 1 2 3 4 5 9 10 8 14 11 6 7 12 25 29 31 28 27 26 32 30 REPLACEMENT PARTS MODEL S210A ...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODEL S210A 22 24 18 20 21 23 Leg and Leg Parts ...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODEL S210A 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal ...

Страница 29: ...k Legs 4 per pkg HEAT SHIELD REQUIRED WITH LEGS 71115 WSHS 210 Heat Shield BLOWER H7917 BLWR FSB700 SS Blower Kit FS Woodstoves OUTSIDE AIR KITS 71111 OUTAIRK L Outside Air Kit Leg 71112 OUTAIRK P Outside Air Kit Pedestal MISC H8159 TSPK B Touch Up Paint Metallic Black 12 oz Aerosol H5308 W LEGF LBRKT Leg Fastening L Brackets 4 per pkg Tie down kit to be used in mobile or modular homes ref form 50...

Страница 30: ...nt sides and rear as indicated NOTICE All mobile home installations require outside air kits OAK Clearance dimensions are to flue collar If a single wall connector pipe with shield is used a 1 inch air space is needed between pipe and shield Shield attaches to rear of stove pipe and must run from stove top to ceiling Pipe shield shall be UL listed PIPE INSTALLATION A C E G M Single Wall Residentia...

Страница 31: ...binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from ...

Страница 32: ...ways give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this system please contact your dealer Innovative Hearth Products LLC IHP 1769 E...

Отзывы: