NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Up to * 6” (153 mm)
6”
(153 mm)
min.
6”
(153 mm)
min.
6” (153 mm)
min.
Figure 1 -
Floor Protection Requirements
* NOTES:
When installed at clearances less than 6”, the floor
protection is only required to extend to the wall. Refer to
Page 5
for chimney/venting floor protection requirements and
recommendations.
Rear
Front
Top View
Floor Protector
Standard residential, commercial or manufactured home installation. These
appliances require the following minimum clearances to combustibles:
Figure 2
Combustible
Combustible
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
NE PAS ENLEVER CETTE ÉTIQUETTE DÉGAGEMENT MINIMUM POUR LES
MATÉRIAUX COMBUSTIBLES
Freestanding Stove Installation / Installation Du Poêle Autonome
Manufactured (Mobile) Home, Residential or Commercial Installation /
Installation Résidentielle Ou Dans Une Maison réfabriquée (Mobile)
A - Side wall to unit
4” (102 mm)
B - Back wall to unit
2” (51 mm)
C - Side wall to unit Corner
1” (25 mm)
D - Max. Depth of Alcove
u
24” (610 mm)
E - Flue to Wall
v
3 " (76mm)
u
Minimum Alcove Measurements - Height 48” (1220 mm) x Width 31”
(788 mm) x Maximum Depth 24” (610 mm)
v
See vent manufacturer to verify clearances
Table 1
Combustible
Rear Wall or Alcove - Clearance to Combustibles
Figure 3
Corner - Clearance to Combustibles
B
A
*E
D
A
E*
C
C
Combustible
Combustible
IMPORTANT
•
Minimum clearances specified may not allow
for ease of operation and maintenance (please
take this in to account when planning the instal-
lation). If installed to the minimum clearances,
removal of the appliance may be necessary for
servicing.
•
Recommended clearance zone from the front
of the appliance to combustibles is 4 feet mini-
mum.
•
Clearances to combustibles for the appliance
can only be reduced by means approved by the
regulatory authority.
CLEARANCES - Montage™ 32FS
*NOTE:
Refer to pipe Manufacturer's installation
instructions for minimum pipe clearances.
*NOTE:
Refer to pipe Manufacturer's installa-
tion instructions for minimum pipe clearances.