background image

8

Assembly

Figure 5

  Locate bag labeled Figure 5. Locate Right 
Pedal Tube Assembly. Secure Pedal Tube 
assembly to the Handrail Assembly with one 
M10*81.5 Hex Bolt and one M10*1.5 Hex 
Nut. Please ensure that Pedal arm is aligned 
in the center of roller wheel while tightening 
M10*81.5 (Figure 5a). Repeat for the left 
side.

Note:

  It is recommended that 2 adults 

align and secure the Pedal Tube Assemblies 
to the Handrail Assemblies. 

Figure 4

  Locate bag labeled Figure 4. Lift and place 
left Linkage onto Sleeve and align holes.  
Secure Linkage to unit using four M8*12 
mm Hex Bolts. Repeat for right side.

Note:

 The Linkage is secured to the sleeve 

with three M8*12 Hex Bolts on the top of 
the Linkage and one M8*12 Hex Bolt on the 
bottom of the Linkage.

Figure 4

Figure 5

M8*12 HEX BOLT

M10*81.5 HEX BOLT

M10*1.5 HEX NUT

SLEEVE

LINKAGE

HANDRAIL ASSEMBLY

PEDAL TUBE ASSEMBLY

Figure 5a

Содержание CDT

Страница 1: ...Manual CDT Elliptical Customer Service 1 800 750 IRON 1 800 750 4766 4009 Distribution Drive Suite 250 Garland TX 75041 www ironmanfitness com CAUTION Read all precautions and instructions in this manual before using this equipment ...

Страница 2: ...nformation 3 4 Assembly 5 10 Console Instructions 11 16 Monitoring Your Heart Rate 17 Warm Up Exercises 18 Troubleshooting Cleaning Maintenance 19 Parts List 20 Exploded Views 21 Warranty Information 22 Table of Contents ...

Страница 3: ...t be placed under the unit to protect floor or carpet and for easier cleaning 4 Follow safety information in regards to plugging in your unit Do not run the power cord underneath your unit Do not operate the unit with a damaged or frayed power cord 5 Wear comfortable good quality walking or running shoes and appropriate clothing Do not use the unit with bare feet sandals socks or stockings 6 Alway...

Страница 4: ...e Dropping the transmitter might cause damage that could void the warranty 4 Do not use the chest strap if you have a cardiac pacemaker or if your are taking medications for a heart condition Medication or electrical pulses from the pacemaker can interfere with accurate heart rate readings 5 Do not bend the strips inside the chest strap This can cause the chest strap to lose conductivity 6 The che...

Страница 5: ... medication will have on your exercise heart rate If you have heart problems your are not active and or are over the age of 35 years do not use the pre set programs or start an exercise program without first contacting and receiving approval from your physician To avoid the risk of electrical shock always keep the console dry Do not spill liquids on the console Ironman Fitness recommends a sealed ...

Страница 6: ...ption of Figure 8 If you are missing any bags please call Ironman Fitness at 1 800 750 4766 Tools have been provided for use while assembling this product Assembly Figure 1 Locate bag labeled Figure 1 Locate Console Tube Attach Console Tube to Main Frame Slide Tube down into Main Frame Connect Upper Console Wire to Lead Wire Assembly Secure using three M10 80 mm Hex Head Screws extending through t...

Страница 7: ...nd Right Handrail Assemblies Secure Left Handrail Assembly to Console tube by using one Washer one Spring Washer one M10 20 Hex Bolt and one End Cap Repeat for the right side Note The Handrail Assembly will only go onto the Console Tube one way The connector on the middle of the Handrail Assembly will face outwards Figure 3 M5 8 SCREW END CAP M10 20 HEX BOLT SPRING WASHER WASHER CONSOLE TUBE HANDR...

Страница 8: ...nded that 2 adults align and secure the Pedal Tube Assemblies to the Handrail Assemblies Figure 4 Locate bag labeled Figure 4 Lift and place left Linkage onto Sleeve and align holes Secure Linkage to unit using four M8 12 mm Hex Bolts Repeat for right side Note The Linkage is secured to the sleeve with three M8 12 Hex Bolts on the top of the Linkage and one M8 12 Hex Bolt on the bottom of the Link...

Страница 9: ...ew M5X0 8 12 Repeat for other side Note Do not overtighten screw this will damage Bracket Cover Figure 6 Figure 7 Locate bag labeled Figure 7 Locate Handlebars Attach Left Handlbar to Handlebar Assy using three M8 16mm Hex Bolts Repeat for other handlebar Figure 7 BRACKET COVER SCREW LEFT HANDLEBAR M8 16 HEX BOLT RIGHT HANDLEBAR CONSOLE TUBE HANDRAIL ASSEMBLY ...

Страница 10: ... pinch wires Figure 9 Figure 8 Locate Console Carefully feed Pulse Wires from the Console down the Console tube Connect Upper Console Wire to the appro priate location on the back of the Console Secure Console to Console Tube using four Screws Note The four Console Screws will already be installed into the back of Console when you remove it from the box Figure 8 10 Assembly CONGRATULATIONS You hav...

Страница 11: ...eys and their different functions CONSOLE BUTTONS MODE To set function value for TIME DIST CAL PULSE RESET Return to main function mode in STOP mode and clean all preset function values at zero START STOP To start or stop training RECOVERY To test heart rate recovery status UP To select training mode and adjust function value up DOWN To select training mode and adjust function value down ...

Страница 12: ...to 0 00 Each preset increment or decrement is 0 1 KM or ML between 0 00 to 99 90 CALORIES Count up No preset target Calories will count up from 0 to maximum 990 with each 1 cal increment Count down If training with preset target Calories will count down from preset calories to 0 Each preset increment or decrement is 10 cal from 0 to 990 cal PULSE Displays your current heart beat figures as soon as...

Страница 13: ...y room temperature 3 To Reset Console press and hold the START STOP button for 2 seconds Note The values calculated or measured by the console are for exercise purposes only not for medical purposes BMR Basal Metabolic Rate metabolism is the energy measured in calories expended by the body at rest to maintain normal body functions BMI Stands for Body Mass Index BMI is a measure which takes into ac...

Страница 14: ...ash on display Use the UP DOWN keys to set Tension for this interval Press ENTER to confirm value Repeat for Interval 2 10 Press START STOP to begin exercising Grasp Pulse Grips loosely with both hands to activate PULSE function You can change the tension level at any time during your workout session by pressing the UP DOWN buttons If the tension level is changed during your exercise session this ...

Страница 15: ... this program Press MODE and set values for TIME DISTANCE KCAL AGE and TARGET HEART RATE Use the UP DOWN keys to adjust the values Press MODE after correct value shows on display Press START STOP to begin exercising Grasp Pulse Grips loosely with both hands to activate PULSE function You may also choose the TARGET HEART RATE WORKING PROGRAM under the 3 main HEART RATE PROGRAMS This allows the user...

Страница 16: ...t Grasp the Pulse Grips Timer will count down from 60 seconds Your personal fitness will display on the screen F1 F6 F1 Excellent F2 Good F3 Fair F4 Below Average F5 Poor F6 Very Poor 16 Console Instructions Body Type Female Male Athlete 17 10 Lean 17 22 10 15 Average 22 25 15 18 Above Avg 25 29 18 20 Overweight 29 35 20 25 Obese 35 25 Body Fat Body Type Range Underweight 18 5 Ideal 18 5 25 Overwe...

Страница 17: ... fitness During your first several months of exercising the AHA recommends aiming for the lower part of the target heart rate zone 60 then gradually progressing up to 75 According to the AHA exercising above 75 of your maximum heart rate may be too strenu ous unless you are in top physical condition Exercising below 60 of your maximum will result in minimal cardiovascular conditioning Check your p...

Страница 18: ... tendons and ankles QUADRICEPS STRETCH With one hand against a wall for balance reach back and grasp one foot with your other hand Bring your heel as close to your buttocks as possible Hold for 15 counts then relax This will stretch your quadriceps and hip muscles INNER THIGH STRETCH Image not Shown Sit with the soles of your feet together and your knees outward Pull your feet toward your groin ar...

Страница 19: ...irmly inserted into the sockets Check to make sure that the batteries in the chest strap are installed correctly Replace the chest strap batteries Check to see if the receiver is properly installed Check to see if the chest strap is being properly worn by user if skin is extremely dry then moisten contact points on chest with water and try again No HR signal or incorrect HR signal Computer is rece...

Страница 20: ...CREW WASHER M5 0 8 14 3 21A8 319 00237 IDLER WHEEL BRACKET ACHIEVER 1 01HL 307 00110 D C MOTOR ASS Y CENTER G ACHIEVER CDT 1 0HVY 331 00095 BALL BEARING 6204ZZ 2 2HRQ 323 00437 HANDRAIL UPPER LEFT CDT 1 0JEG 302 00109 C RING A 20 1 2HRT 323 00434 PEDAL TUBE ASSY LEFT CDT 1 22LR 302 00108 C RING A 16 1 2HRP 323 00436 HANDRAIL UPPER RIGHT CDT 1 2H4J 302 01349 RETAINING RING ACHIEVER 1 2D3C 305 00150...

Страница 21: ...PY 2HT7 3 6 0JUU 2HRH F D E E I I 2HRJ 2GQR 2 2HUT 2GSJ 2GTU N 2GVB P P 2GTN 2GTX 2HRN 2HRM 2GTQ 2 2GTW 2 2GTS 2GTM 2GTY 2GTZ 2GU0 2 21X8 3 0K2W 3 21AA 22LR 2HNU 0JEG 2H4J 0HVY 2 2H66 2HRC 2GS1 0JEE 4 2HRS 2 A 2D3G 2 2DBH 8 2HRT B Q 4 0HVX 22RR 2 21BA 2 4 0K4R Q 2H7B 2DUW J 2CTC 2CZP 2 2CU9 261H 8 2 2CS3 2 2CU8 2 2 0KR0 2 4 0J4Z 2CRJ 8 2 27JR 4 C 0HVQ 2HRG 0HVQ 2 0HVQ 21ZR 3 2HK7 16 0K94 2HM5 0J4J...

Страница 22: ...u must prepay any shipping charges export taxes custom duties and taxes or any other charges associated with transportation of the parts or Product In addition you are respon sible for insuring any parts or Product shipped or returned You assume the risk of loss during shipment You must present Ironman with proof of purchase documents including the date of purchase Any evidence of alteration erasi...

Страница 23: ...e 1 800 750 IRON 1 800 750 4766 Ironman Fitness 4009 Distribution Drive Suite 250 Garland TX 75041 www ironmanfitness com Ironman and M dot are registered trademarks of the World Triathlon Corp used here by permission ...

Отзывы: