6.
Hardware Specifications
•
Mechanical Size
o
IriShield
TM
-USB BO Board: Main board (details from page 9)
47 x 40 x 6.9 mm (1.8 x 1.6 x 0.3 in)
o
Camera Module: specialized iris camera module (details in page 15)
31 x 27 x 23.3 mm (1.2 x 1.1 x 0.9 in)
※
Details for alignment of IR LED on Camera module: page 19
o
FPCB Cable: Interface cable between IriShield
TM
-USB BO board and camera module
(details in page 12)
41 x 21 x 0.3 mm (1.6 x 0.8 x 0.01 in)
o
130mm Ass’y Cable: Communication cable with host (details in page 10)
140 x 5.4 x 2.8 mm (5.5 x 0.2 x 0.1 in)
o
15
Φ
IR-Filter: Band pass filter to remove visible light reflection in iris image
15 x 15 x 1.1 mm (0.6 x 0.6 x 0.04 in)
※
Should be assembled in front of camera module (details from page 17)
•
Power Requirements
Required Voltage
Vin
Min
Max
Recommend
Single USB Power (DC +5V ± 5%)
Absolute
3.4V
6V
•
Infinite loops are one of the most common problem that plagues developers. They
can occur in any programming language, in any application and in any coding style.
If infinite loop occurs, it can be solved by turning off/on the power switch. We
strongly recommend installing switching circuit or power control switch to fix the
problem.
•
Power Management
Mode
Current
Description
Active
MAX 430mA
Fully operating
Standby
MAX 80mA
Standby Mode
Sleep
MAX 60mA
Sleep Mode
•
Environmental
o
-20°C to +60°C Storage
o
0°C to +50°C Operating