IRIS Touch
Quick Installation & Maintenance Guide Version 1.1
6.
Installing the IRIS Touch Dialler
Use the following procedure to install your IRIS Touch dialler:
Mounting
Choose a suitable location taking into consideration the routing of both power and dialler interface cables,
within the alarm panel or separate enclosure. Secure the dialler within the enclosure using the fitted
standoff or the alternative self-adhesive feet.
Note: For EN50131-10 compliance you must use the supplied standoff and not the self-adhesive feet.
Power
The IRIS Touch dialler can be powered from a separate or Aux 9-28V DC power supply specified to deliver
up to 1A current using the screw terminals indicated in
Section 4 “Board Configuration”
.
Note: For Radio & Telecoms Terminal Equipment Directive compliance the power cable must be no longer
than 3 meters in length.
Fit the power cable. DO NOT APPLY POWER TO THE DIALLER UNTIL INDICATED.
Connections
Connect cables to the PCB for your system as shown on in
Section 4 “Board Configuration”
.
Ethernet enabled systems (IRIS Touch 420NG & 440NG): Ethernet socket ETH1.
Connect the Ethernet cable from ‘ETH1’ to the local IP router/switch or socket that has been
allocated for the LAN/WAN network IP connection.
GPRS/3G enabled systems (IRIS Touch 400NG & 440NG): Cell Ant. Fit the supplied T-bar GPRS/3G
antenna but do not fix in place until after performing the GPRS/3G network scan.
Note: An external GPRS/3G antenna can be fitted if required.
Panel Connections:
With the IRIS Touch dialler you have 2 connection methods for the alarm and upload/download
communications as detailed below:
Dial C RS232
Dial capture port for alarm connection from the PSTN module.
RS232 DCE Header for upload/download connection (RS232RJ45 cable required).
Ethernet EDP
Ethernet ETH2 for alarm and upload/download connections to the Siemens SPC Ethernet (RG45)
connector. This connection uses the EDP alarm protocol (Converting to SIA alarm format for receipt
via the IRIS Secure Apps software package).
Note: The IRIS Dialler will need to be software version 2.20.0 or higher to support this feature.
For more details on the cable requirements / connections please see detail on next page.