Страница 2: ...alling the IRIS Touch Dialler 6 Mounting 6 Power 6 Connections 6 GPRS 3G SIM card IRIS Touch 400NG or 440NG 9 Dial Capture 9 RS232 9 Ethernet 9 Switch On and Test 9 Configuration 9 Panel Configuration 11 Testing 12 7 Maintenance 12 Confirm Current Status 13 Check Software Version Reflash 13 Communication Paths Checks 13 Test alarm panel alarms and communication to ARC 13 8 Specifications 14 ...

Страница 3: ...reen as standard for configuration local alerts and allows diagnostic and tests to be performed by the engineer Polling and alarm transmission are performed via the Ethernet or GPRS 3G communication paths 4G and CDMA on request to the monitoring centre using the IRIS Secure Apps monitoring software This manual describes a quick guide to the installation of products from the IRIS Touch For the full...

Страница 4: ...uration IRIS Touch SYS LED LED Colour Indication Yellow flashing Not currently configured or indicating that there are some current faults outstanding Yellow constant Communicating and no current faults flickers on every poll DC power Pin inputs RS485 Dial capture port RJ11 and screw terminals SIM card holder Ethernet 2 SYS LED Ethernet 1 Expansion board connector GPRS 3G antenna Serial TTL RS232 ...

Страница 5: ...LAN network details are required in order to connect the IRIS Touch The following information should be obtained from the customer Fixed IP address or DHCP Fixed DHCP If using DHCP then the following information will not be required as it will be assigned by the network IP address Gateway address Subnet mask address GPRS 3G SIM Card and Access Point Name If the installation uses GPRS 3G then a SIM...

Страница 6: ...on in Section 4 Board Configuration Ethernet enabled systems IRIS Touch 420NG 440NG Ethernet socket ETH1 Connect the Ethernet cable from ETH1 to the local IP router switch or socket that has been allocated for the LAN WAN network IP connection GPRS 3G enabled systems IRIS Touch 400NG 440NG Cell Ant Fit the supplied T bar GPRS 3G antenna but do not fix in place until after performing the GPRS 3G ne...

Страница 7: ...nd Serial connections Dial Capture for the Alarms Connect the centre two wires Red Green to the A B Terminal Blocks Polarity not important Serial DCE Header Connection for Upload download Connect the Serial DCE connector from the Iris to the SPC Serial Port 2 RJ45 connector RS232RJ45 connection cable ordered seperatly ...

Страница 8: ...tion Maintenance Guide Version 1 1 IRIS Touch to SPC panels using Ethernet Connection EDP alarm integration Ethernet Connection for EDP alarms Upload download Connect the ETH2 RJ45 connector from the Iris to the SPC Ethernet RJ45 connector ...

Страница 9: ...S232 RJ45 connection socket on the SPC panel with the RS232RJ45 connection cable ordered separately Ethernet Ethernet EDP alarms and upload download enabled systems Connected the ETH2 RJ45 to the Ethernet RJ45 connection socket on the SPC panel with a standard Ethernet cable Switch On and Test To confirm power is applied look for the indicator SYS LED flashing yellow on the IRIS Touch dialler boar...

Страница 10: ...allers Menu and enter in the installer code that you had setup beforehand and then select the Installation Wizard as indicated next IRIS Touch 420NG or 440NG without GPRS 3G or after network scan completed Installation Wizard Select the Installation Wizard and follow the on screen prompts Once you have completed the Installation Wizard and setup any additional panel interface configuration via the...

Страница 11: ...n if needed Panel Configuration Panel configuration for dial capture If you are connecting the IRIS Touch dialler via the dial capture method which is connecting the Telecoms module to the dial port of the IRIS Touch you will need to configure the following options Telephone Number The 12 digit format of the monitoring centre IP address e g 192 168 0 34 would become 192168000034 To select routing ...

Страница 12: ... and confirm these are received at the monitoring centre The IRIS Touch dialler will give a visual indication of the current system status via the SYS LED If this is yellow constant the current setup of the dialler is reporting OK yellow flashing means the dialler is reporting some trouble events To further investigate any faults or to perform checks the IRIS Touch dialler gives engineers the opti...

Страница 13: ...the installation documentation Enter the correct reflash password and you will then have the following options The Chiron Reflash server IP address will already be setup under the Reflash IP Address but if using an alternative Reflash IP address then change the IP address Once you have the correct reflash IP address entered press the Reflash Now to connect to the server and check if there is a lat...

Страница 14: ...k Serial interface to alarm panel RS485 TTL RS232 x 2 Note RS232 cabling must not exceed 30 meters PIN Inputs interface to alarm panel Maximum input voltage range 0V to 24V Input low alarm threshold 1V Input high restore threshold 2V Internal pull up impedance 10K to 3 3V supply Alarm protocols SIA level 1 to 3 reference SIA DC 03 1990 01 R2003 10 Contact ID reference SIA DC 05 1999 09 Fast format...

Страница 15: ...TNV interface of single line telecommunications equipment such as telephones alarm panels etc Power Interface SELV for connection to a DC supply Inputs SELV for connection to alarm output pin Conformance European Directives The IRIS Touch complies with the following European Directives 1999 5 EC Radio Telecoms Terminal Equipment Directive 2006 95 EC Low Voltage Directive 2004 108 EC Electromagneti...

Страница 16: ...nquiries 41 435 080 870 Email sales chironsc com www chironsc com CHIRON SECURITY COMMUNICATIONS AG BAARERSTRASSE 19 6300 ZUG SWITZERLAND The information contained is supplied without liability for any errors or omissions No part may be reproduced or used except as authorized by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media...