SPECIFICATIONS FOR MODEL 600 ULTRA FLAME ROD

ELECTRICAL

Primary Input Power

–  85 to 132 VAC, or 170 to 264 VAC, 50 or 60 Hz

Input Current, Monitoring only

–  .07 A at 115VAC, .035 A at 230 VAC

Input Current, Ignition on

–  .3 A at 115VAC, .15 A at 230 VAC
      plus current to ignition transformer (5 AMPS MAX.)

Ignition  Command  Input

–  12 to 50 VDC or 85 to 264 VAC, 50 or 60 Hz
     (using labeled DC and AC inputs)

Command  Current

–  .02 A DC at 50 VDC, .015 A RMS at 230 VAC

Maximum Capacitance Load

–  1.0 nF, flame rod drive to ground (through wire insulation)

OUTPUTS

Flame Relay

–  DPDT contacts, rated 5A at 125 VAC, 277 VAC, and
   30 VDC

Ignition Transformer Relay

–  DPST contacts, rated 5A at 125 VAC and 250 VAC

Ignition Coil Drive

–  A capacitance of 4.4 uF is discharged from 230 VDC
    through the ignition coil tap at the AC line rate by a
   4A, 400 V SCR

ENVIRONMENTAL

Ambient Temperature

–  Controller 0°C to 60°C (32°F to 140°F)

SAFETY

Flame rod voltage

–  175 VAC at 115/230 VAC input

Flame rod current (not firing)

–  Maximum current to ground <0.5ma

Rev: 0905

Содержание 600 Ultra

Страница 1: ...FLAME MONITORING SYSTEM WORLD LEADER IN FLAME MONITORING MODEL 600 ULTRA FLAME ROD APPLICATION MANUAL ...

Страница 2: ...vided The flame rod itself can be shorted to ground indefinitely without harm to the unit If the flame rod becomes fouled so that an unreasonably large amount ofAC current flows from the flame to ground first a yellow ROD FOULED LED is turned on If the AC current in creases further a ROD FAULT LED is turned on and the flame relay is opened Note that the Model 600 Ultra controller distinguishes bet...

Страница 3: ...ntroller Remove the three black screws on each side of the controller lift off the top assembly unplug the two 5 A fuses plug in the two 5 A fuses and reassemble the controller FRONT PANELFUNCTIONSAND SETUP Six numeric LED digits arranged vertically provide a graphic visual display of the flame signal If the Flame Rod is connected and the AC power is on green POWER LED will be on and there is no f...

Страница 4: ... ROD GOOD SIG A ROD ROD FOULED GAIN 1 GAIN 2 NO JMPR MAX GAIN 4 SIGNAL Relay On WEAK SIGNAL Relay On POOR SIGNAL Relay Off MODEL 600 ULTRA GND 115 VAC 50 60 HZ 230 VAC 50 60 HZ SIG B ROD XFMRXFMR AC IGN COM IGN DC IGN RF A RF A RF A RF B GAIN 3 RF B RF B TURN IGN ON TO XFMR LINE INPUT SELECT FOR LINE INPUT P1 P2 P3 P4 P5 ...

Страница 5: ...D XFMRXFMR AC IGN COM IGN DC IGN RF A RF A RF A RF B GAIN 3 RF B RF B TURN IGN ON TO XFMR LINE INPUT SELECT FOR LINE INPUT ROD FLAME ROD IGNITION FLAME IGNITION COIL GAIN 1 GAIN 2 NO JMPR MAX GAIN 4 GAIN 3 5A OR 5A 5A OR 5A FLAME ROD ONLY AC IN GND TO IGN XFMR TAP COIL COIL ROD P1 P2 P3 P4 P5 GND C B A COIL TIP GND GND 230 VAC POSITION 115 VAC POSITION FIGURE 2 WIRING FOR MODEL 600 FLAME ROD ULTRA...

Страница 6: ...rent 02 A DC at 50 VDC 015 A RMS at 230 VAC MaximumCapacitanceLoad 1 0nF flame rod drive to ground through wire insulation OUTPUTS FlameRelay DPDT contacts rated 5Aat 125 VAC 277 VAC and 30 VDC IgnitionTransformerRelay DPST contacts rated 5Aat 125 VAC and 250 VAC IgnitionCoilDrive Acapacitance of 4 4 uF is discharged from 230 VDC through the ignition coil tap at theAC line rate by a 4A 400 V SCR E...

Отзывы: