background image

QPSK/IP   DEMODULATOR 

 

 

The  TS/IP  function  block  is  valid  when  the  TS/IP  streaming  board  is  installed  into  the  This 
equipment

-

x. You can set it as 

‘IP In’ or ‘IP Out’, which is exclusive to each other (refer to section

 

7.4.6).

 

The  Mux/Filter  function  block  is  standard  option  and  could  be  configured  as  internal  2-way 
‘multiplexer’ or ‘filter’, which is exclusive to each other. Also you can turn on or turn off the block 
(refer to section 7.4.6).

 

 

 

 

 

 

 

 
 
 

 

Common Interface

 

 

 

Mux/Filter (option)

 

 
 
 

 

 

 

 

Figure 6.1 Function Block Diagram

 

 

START TO USE

 

 

The  device  allows  you  to  configure,  control  and  monitor  through  the  Keypad  and  front  panel 
display when a remote control system is not used.

 

Main Menu

 

Turn on the device and wait for 8 to 10 seconds, while the device will complete self inspection 
and configuration. The top row of the  LCD shows the name of the device. The local IP  address 
is displayed on the bottom row of the  LCD.

 

Note: 

the  local  IP  address  and  unit  name  can  be  changed  in  the  System  Menu  (refer  to 

section 7.4.1 and 7.4.3 System).

 

Use the 

<ENTER>-key 

to enter on the Main Menu. The <  >-and<  >-keys are used to choose 

between the three main menus.

 

 

 

9

 

 

LAN 

Rs232

 

Keyboard, Menu display and LAN control

 

TS/IP output port 
(option)

 

TS/IP Input Port 
(option)

 

A/V 

Buffer

 

MPEG-2

 

Decoder

 

Tuner Input Port

 

ASI Input Port

 

AES/EBU (option)

 

ASI2/SDI output 
port

 

ASI1 output port

 

TS

 S

w

itc

h

 Ma

tr

ix

 

Содержание IRD-6000

Страница 1: ...QPSK IP DEMODULATOR QPSK IP Demodulator User Manual IRD 6000 QPSK IP Demodulator QPSK IP Demodulator User Manual V1 0 Version 1 0...

Страница 2: ...LEDS 6 4 3 Liquid Crystal Display 6 4 4 Keypad 7 4 5 Common Interface 7 5 Real panel 8 5 1 Power Supply 8 5 2 Output Connectors 8 5 3 ASI Input Connector 8 5 4 RS 232 Interface 8 5 5 Ethernet Interfac...

Страница 3: ...ion The appropriate servicing authority must be informed For example safety is likely to be impaired if the device fails to perform the intended measurements or shows visible damage WARNINGS Do not us...

Страница 4: ...00 S C T D S2 S C T D S2 IP TS DS3 Input Loop through DVB S2 Input DVB C Input DVB T Input PCMCIASlot ASI TS Input Output Audio Embedded SDI Output Ethemet Remote Control BNC Video Output A V Output B...

Страница 5: ...he table POWER REQUIREMENT Input voltage 90 260 Vrms auto select Frequency 47 to 63 Hz Power 50 VAmax 30 VAtypical Current 110 V 0 27Aor 240 V 0 125Atypical Caution Table 3 1 Power requirement Be sure...

Страница 6: ...s of input signal source which includes IP input QPSK signal input and DVB ASI TS input Liquid Crystal Display The 2 x 20 character Liquid Crystal Display LCD shows all the required information about...

Страница 7: ...are used to select between the main menus or sub menus or programs When you stand on the preferred menu and the parameter is active they are also used to change the numerical values Selecting a digit...

Страница 8: ...75 Ohm impedance The ASI interface B18 and B19 are used as a redundant output of B8 and B9 out Note the B8 B18 interface could be configured as SDI with Audio embedded Please refer to Chapter 7 3 5 AS...

Страница 9: ...rough the Keypad and front panel display when a remote control system is not used Main Menu Turn on the device and wait for 8 to 10 seconds while the device will complete self inspection and configura...

Страница 10: ...In refer to section 7 4 6 Optional Function 7 2 2 QPSK COFDM QAM DVB S2 The tuner setting menu is different and exclusive according to DVB S DVB T DVB C DVB S2 tuner is equipped To receive the QPSK C...

Страница 11: ...ctivate the LNB 22 kHz control signal to the LNB On or Off Operation Mode select the appropriate operation mode in the menu There are QPSK 1 2 2 3 3 4 4 5 5 6 8 9 9 10 and 8PSK 2 3 3 4 3 5 5 6 8 9 9 1...

Страница 12: ...n out board is installed and the TS IP streaming board is set to IP Out Refer to section 7 4 6 Outputs Status CI Decoder ASI ASI2 SDI Mux Filter Ethernet option 7 3 1 Ethernet Figure 7 3 Outputs Menu...

Страница 13: ...es detected by this equipment x The programs could be coming from ASI input Tuner TS IP input or the internal CI de encryption block Use the or key to roll up or down between the program names and use...

Страница 14: ...to be set Audio PID and Embed Audios Audio PID press the keys to choose the audio PID from 1 4 Embed Audios there are 4 options none one two two and one 7 3 6 Mux Filter Note this Mux or Filter menu i...

Страница 15: ...s to roll up the program names where a number in front of the program name indicates the input source 0 xxxxx displays the program name which comes from ASI input 1 xxxxx displays the program name whi...

Страница 16: ...ked into one IP stream Therefore each IP stream carries only one program and be delivered to the specified Multicast or Unicast IP address You can configure maximum 6 IPTV channels Multicast Setup use...

Страница 17: ...perties Factory Settings Optional Function Machine Type Figure 7 4 System Menu 7 4 1 Local Setup Each This equipment x has an IP address a network sub mask and a gateway These must be set to an approp...

Страница 18: ...onfirm or to scrap by pressing EXIT key 7 4 7 Setting Machine Type This setting is reserved for factory setting and you are not allowed to access this menu FAQ 1 Why is there nothing in the LCD Answer...

Страница 19: ...bol Rate 2 45 Mb s SCPC or MCPC Rolling Off Coefficient 0 20 or 0 35 FEC 2 3 3 4 5 6 6 7 7 8 Reeds Salomon Decoding 204 188 T 8 I 12 DVB C QAM Demodulation Connector IEC Female 7 8 MHz or F Female 6 M...

Страница 20: ...anced FFT mode 2K 8K Guard Interval 1 4 1 8 1 16 1 32 off FEC Code Rate 2 3 3 4 5 6 and 7 8 Ds3 Input Input Impedance 75 Maximum Output Code Rate 44 736 Mbit s Connector BNC Format Unframed Framing ac...

Страница 21: ...put 1 optional RGB output 1 RCA CVBS output 1 RCA 1 BNC Audio XRL Balance Output 1 General Operating Temperature 0 45 Storage Temperature 20 70 Humidity 85 Power Supply AC 90V 260V 50Hz 60Hz Dimension...

Отзывы: