14
Command Function
Cmd Data
Set Auto-Fan Enable
0x16 p5 = Auto-Fan Enable byte-(0x01)ex
Response Packet
0x16 Same as Get Laser Serial Number Response Packet
Set Auto-Fan Disable
0x16 p5 = Auto-Fan Disable byte-(0x00)
Response Packet
0x16 Same as Get Laser Serial Number Response Packet
Command Function
Cmd Data
Get Options
0x18
Response Packet
0x18 (Get Options Command)
Packet Length
—0x01 to 0xFF. (See above Packet
Characters for description)
P1 = Set Mod-Low byte
– (0x01 or 0xFF “On”, 0x00
“Off”) P2 = Laser life “On Time”—(0x00000000 to
0xFFFFFFFF) P3 = KeySwitch Enable byte
—(0x01
or 0xFF “On”, 0x00 “Off”
Command Function
Cmd Data
Set Mod Low
Grounded
0x15 p1 = Mod-Low
“Grounded” byte-(0x01)
Response Packet
0x15 Same as Get Options Response Packet
Set Mod Low Not
Grounded
0x15 p1 = Mod-Low
“Not Grounded” byte-(0x00)
Response Packet
0x15 Same as Get Options Response Packet
Command Function
Cmd Data
Set laser On Time
0x17 p1 = Set Laser
“On Time” quad byte-
(0xXXXXXXXX).
This value can be any value from 0x0 to
0xFFFFFFFF.
Response Packet No response packet. This Command assigns a Laser
“On
Time” to memory.