OPERATOR’S
MANUAL
RS232 Interface
http://www.iradionlaser.com
Страница 1: ...OPERATOR S MANUAL RS232 Interface http www iradionlaser com ...
Страница 2: ...e 9 11 Response Packet Format 10 12 Packet Characters 10 13 The Command Functions list 15 Table of Figures Figure 1 Setup Wizard to start installation 3 Figure 2 select installation destination 3 Figure 3 Confirm installation 3 Figure 4 Complete installation 4 Figure 5 Desktop Icon 4 Figure 6 Comm Writer II startup view 7 Figure 7 Select comm port 7 Figure 8 Comm writer connected state view 8 Figu...
Страница 3: ...consists of two files Setup exe and Setup msi Execute the setup msi file Follow the prompts to install the software see figure 1 to figure 4 Windows will ask permission to install the software this will require administrative access to the computer Answer yes By default the software will be installed to the default program file location In most computers this will be c program files or c program f...
Страница 4: ...3 Figure 1 Setup Wizard to start installation Figure 2 select installation destination Figure 3 Confirm installation ...
Страница 5: ...4 Figure 4 Complete installation Figure 5 Desktop Icon ...
Страница 6: ... computer had failed to locate a serial port installed The software will not function without a working serial port 4 7 Click on the Start monitor loop button to open the comm port and start automatically polling the status of the laser see figure 6 Note You have to select a comm port first otherwise this button will be disabled Upon success on initializing the comm port the status bar bottom of t...
Страница 7: ...ser fault Laser VDC Laser serial Laser voltage Setting Rated power Measured power Auto fan Firmware version Mod low ground 4 11 If the communication failed the application will display a failure status in the status bar The program will time out after 10 seconds and signal a failure if the communication did not respond A dialog box will be shown to reset the serial port or to exit the application ...
Страница 8: ...itialize comm button to initialize the selected port Selected comm port Serial Results Status Results Command Window Status Lights Green ON Read OFF Flt Send Command Initialize Comm Port Button Comm Port Selected Connection TRUE Connected FALSE NOT Connected Close Application Get Option Results ...
Страница 9: ... Send command button is enabled because connection is true Figure 8 Comm writer connected state view Figure 9 Comm writer error message Grayed out Connected Connected Port Connection Failure Communication failed Click YES to reset the application or NO to exit the application ...
Страница 10: ...gth Data Data End Check End 8 Packet Characters Start character Cmd 2 characters ascii hex format 00 FF Length 2 characters ascii hex format 00 FF Data 0 to n characters ascii hex format 000000 N FFFFFF N Data End character Check 2 characters ascii hex format 00 FF End 2 characters carriage return and line feed Length Number of characters in the packet includes Start to End characters A Cmd packet...
Страница 11: ...ata 0 to n characters ascii hex format 000000 N FFFFFF N Data End character Check 2 characters ascii hex format 00 FF End 2 characters carriage return and line feed Length Number of characters in the packet includes Start to End characters Command Function Cmd Data Get Status 0x10 Response Packet 0x10 Get Status Command Packet Length 0x01 to 0xFF See above Packet Characters for description P1 Lase...
Страница 12: ...Fault Status 0x01 On 0x00 OFF P11 Get Laser VDC 0x0000 to 0xFFFF 85mV count Packet Termination Command Function Cmd Data Set Simmer Frequency 0x11 p3 Simmer Frequency byte 0x31 to 0xC7 200 KHz to 50 KHz 5 KHz steps Response Packet 0x11 Same as Get Status Response Packet Set Simmer Duty Cycle 0x12 p1 Simmer Duty Cycle byte 0 to 20 1 steps Response Packet 0x12 Same as Get Status Response Packet Set ...
Страница 13: ... s measured power at the nominal set voltage the enable Auto Fan the Firmware Version p1 The first 4 characters or p1 packet are the serial number expressed in hexadecimal up to FFFF or 65 535 lasers and represents the serial number accumulated irrespective of the power rating of the laser p2 Laser Set Voltage ok Retrieving Laser Set Voltage is part of the Get Laser Serial Number Command code This...
Страница 14: ... if Auto Fan is enabled 0x00 if Auto Fan is disabled p6 Firmware Version Retrieving Firmware Version is part of the Get laser Serial Number Command code This Command will return a p6 Packet this byte will return a value between 0x00 and 0xFF The format is XX Example 04BF 01D8 3C 55 01 0A laser SN 1215 laser voltage set to 40V laser power set to 60W laser power measured 85W Auto Fan enabled 01 Firm...
Страница 15: ...ption P1 Set Mod Low byte 0x01 or 0xFF On 0x00 Off P2 Laser life On Time 0x00000000 to 0xFFFFFFFF P3 KeySwitch Enable byte 0x01 or 0xFF On 0x00 Off Command Function Cmd Data Set Mod Low Grounded 0x15 p1 Mod Low Grounded byte 0x01 Response Packet 0x15 Same as Get Options Response Packet Set Mod Low Not Grounded 0x15 p1 Mod Low Not Grounded byte 0x00 Response Packet 0x15 Same as Get Options Response...
Страница 16: ...70 KHz 110C8E 9C Set Simmer Frequency 75 KHz 110C84 8B Set Simmer Frequency 80 KHz 110C7C 99 Set Simmer Frequency 85 KHz 110C75 8B Set Simmer Frequency 90 KHz 110C6E 9A Set Simmer Frequency 95 KHz 110C68 8D Set Simmer Frequency 100 KHz 110C63 88 Set Simmer Frequency 105 KHz 110C5E 99 Set Simmer Frequency 110 KHz 110C5A 95 Set Simmer Frequency 115 KHz 110C56 8A Set Simmer Frequency 120 KHz 110C52 8...
Страница 17: ...0C3A 93 Set Simmer Frequency 175 KHz 110C38 8A Set Simmer Frequency 180 KHz 110C37 89 Set Simmer Frequency 185 KHz 110C35 87 Set Simmer Frequency 190 KHz 110C34 86 Set Simmer Frequency 195 KHz 110C32 84 Set Simmer Frequency 200 KHz 110C31 83 Set Simmer Duty Cycle 0 120C00 80 ...
Страница 18: ...uty Cycle 15 120C0F 96 Set Simmer Duty Cycle 16 120C10 81 Set Simmer Duty Cycle 17 120C11 82 Set Simmer Duty Cycle 18 120C12 83 Set Simmer Duty Cycle 19 120C13 84 Set Simmer Duty Cycle 20 120C14 85 Set Pulse Stretch 0 us 130C00 81 Set Pulse Stretch 1 us 130C0A 92 Set Pulse Stretch 2 us 130C14 86 Set Pulse Stretch 3 us 130C1E 97 Set Pulse Stretch 4 us 130C28 8B Set Pulse Stretch 5 us 130C32 86 Set ...