background image

 Series eWAVE  

 

 

                   Page 9 

 

 

 

       LT286 April 09, 2020    

 IMPORTANT INSTRUCTIONS FOR OUTDOOR INSTALLATIONS 

1.  During installation, to maintain the water resistance of the junction box, it is necessary to make sure that all the 

components of the fitting are perfectly matched and placed in their position and sequence along the conduit 
hose (see pictures); 
 

2.  Furthermore, the cut end of the conduit attached to the fitting must be cut uniformly to allow correct pairing and 

assembly, which is crucial for ensuring water resistance. Therefore, make sure that the main ring nut of the 
fitting that fixes the conduit is firmly tightened. If intended for outdoor installation, a water-tight conduit must be 
employed. 

 

 

 

MAINTENANCE INSTRUCTIONS  

 

 

Before cleaning, make sure the power has been turned off at the circuit breaker 
panel and that the heating element of the heater is cool. 
Never immerse the appliance in water or any other liquid. 
Cleaning and maintenance must be performed by the user and not by 
unsupervised children. 

 
1.  It is important that eWAVE units are regularly cleaned to ensure long and efficient operating life. 
2.  To clean, use a soft damp cloth and then dry thoroughly. 
3.  Make sure all parts are dry before powering the heater. 
4.  eWAVE units should be cleaned and inspected every 3 months. 
5.  Avoid the use of harsh detergents, solvents, and abrasive or aerosol cleaners as they may damage surfaces. 
6.  When cleaning the heater, always inspect the back of the heater for build-up of insects, bird droppings, dust, 

salt build-up, etc. and clean back thoroughly. 

 

TECHNICAL SERVICE 

 

Always disconnect the appliance before doing any maintenance operation. 

 

1.  If the heater is removed from mounting brackets, it should be stored in an undercover dry location. 
2.  Always inspect the heater after high winds, earthquake, vandalism or any other unusual event that may have 

affected the heater. Ensure all parts are dry before powering the heater. 

3.  Any maintenance service, excluding cleaning, must be carried out by an authorized Manufacturer 

representative. 

4.  If you have any question about your appliance, call the local authorized distributor. 

Содержание EW15L12

Страница 1: ... wiring comprise the basic information needed to complete the installation These criteria must be thoroughly understood before proceeding Only personnel who have been trained and understand all applicable codes should undertake the installation Manufacturer representatives are Factory Certified in the service and application of this equipment and can be called on for helpful suggestions about inst...

Страница 2: ...accordance with local codes or in the absence of local codes the National Electrical Code NFPA 70 or the Canadian Electrical Code Part 1 C22 1 The eWAVE heater is designed and manufactured for residential commercial heating applications for indoor and outdoor use according to the Standard for Fixed and Location Dedicated Electric Room Heaters UL 2021 and the Canadian Standard for Electric Air Heat...

Страница 3: ...ONS CAUTION High temperature risk of fire keep electrical cords drapery furnishings and other combustibles at least 3 feet 0 9 m from the front of the heater and away from the side and rear 1 This appliance is intended solely for use as an infrared heater and should not be used for other purposes The manufacturer is not responsible for any damage that could happen for improper use 2 After unpackin...

Страница 4: ...ious harm from an ongoing electric shock a Ground Fault Circuit Interrupter GFCI with rated earth leakage operation not exceeding 30mA must be fitted upstream on the supply line Additionally for ensuring a total disconnection of the unit with a full interruption of the contacts in all poles it s necessary to install a category III combined circuit breaker with contact opening distance of at least ...

Страница 5: ...ature 4 Building materials with low heat tolerance i e plastics vinyl siding canvas tri ply etc may be subject to degradation at lower temperatures It is the installer s responsibility to ensure that adjacent materials are protected from deterioration Some parts of this product can become very hot and cause burns Particular attention has to be given where children and vulnerable people are present...

Страница 6: ... fixed to the wall or to the ceiling by means of the provided supports Ensure that the wall where you intend to install the heater is solid and that no electrical cables or water pipes pass behind it 1 Drill four holes in the wall as shown in the picture 2 Fix two supports on the wall using the proper mounting hardware not included ...

Страница 7: ...upplied screw and bolt 5 Fix the brackets in position by tightening the safety screws 6 Tilt the heater until you can insert a screw in the hole Now the junction box is easy to access 7 Connect the power according to the following diagram 8 After finishing the wiring and closing the junction box cover tilt the heater in the desired angle and insert the bracket screws in the matching holes ...

Страница 8: ...s eWAVE Page 8 LT286 April 09 2020 9 Once the wiring is completed close the connection box with the appropriate screws making sure to position the gaskets between the box and the cover as shown in the figure ...

Страница 9: ...by the user and not by unsupervised children 1 It is important that eWAVE units are regularly cleaned to ensure long and efficient operating life 2 To clean use a soft damp cloth and then dry thoroughly 3 Make sure all parts are dry before powering the heater 4 eWAVE units should be cleaned and inspected every 3 months 5 Avoid the use of harsh detergents solvents and abrasive or aerosol cleaners a...

Страница 10: ...eWAVE Hanging Brackets Kit Part ES314 Item Description Quantity 1 Heater Bracket 2 2 Wall Bracket 2 3 M4x10mm Phillips Pan Scr S S 8 4 M4 Nut S S 4 eWAVE Junction Box Lid Gasket Kit Part ES315 Item Description Quantity 1 Lid 1 2 Gasket 1 3 Screws 2 4 Washers 2 ...

Страница 11: ...anty obligation or liability Provision of this warranty is subject to The eWAVE product must be installed in accordance with the installation instructions and relevant electrical standards and codes The eWAVE product must be maintained and cleaned according to instructions detailed in the installation manual Discoloration of the surface may occur after a period of time this does not constitute a w...

Страница 12: ...Series eWAVE Page 12 LT286 April 09 2020 THIS PAGE LEFT INTENTIONALLY BLANK ...

Отзывы: