Even-GLO
TM
Series GA301
Page 29
Rev. July/2012
8 - Lighting & Shutdown Instructions
Lighting
1. Open manual gas supply valve (ensure gas supply lines have been purged).
2. Turn on switch to energize electric supply.
3. The electronic control module will time begin the ignition period in 3 seconds.
4. The gas valve will open and ignition spark will commence and continue for 20 sec.
5. If flame starts and “is detected”, flame will continue until turned off.
6. If no flame is detected, the gas valve will close after 20 sec. A “wait’ period commences
and lasts approximately 5 sec. and a second trial for combustion commences. The
electronic control will attempt three trials for ignition before locking out for approximately
5 minutes at which time it will automatically try again.
Electronic control of heater can be re-set by de-energizing and re-energizing electric power.
Shut Down
1. Turn off power to electronic control.
2. For longer periods of shut down, also close manual gas supply valve.