Even-GLO
TM
Series GA301
Page 12
Rev. July/2012
5 - Installation Instructions
Power / Gas Specification
High fire rate: Natural -
53,000 btuh
Propane -
47,000 btuh
Low fire rate: Natural -
46,000 btuh
Propane -
40,000 btuh
Gas Supply Pressure
:
Natural Gas: Minimum 6.5 ” W.C. Maximum 14.0 ” W.C.
Propane Gas: Minimum 10.8 ” W.C. Maximum 14.0 ” W.C.
Manifold Pressure:
Natural Gas: Low - 4.0” W.C. High - 5.5” W.C.
Propane Gas: Low - 7.0” W.C. High - 9.8” W.C.
Electric Supply
:
24 VAC, 0.8A
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psig (3.5
KPa)
Installation or repair should only be done by personnel qualified for
the installation of powered gas appliances.