GW-USB-04
LEDs
Debug
/
service LEDs inside the case.
•
LED3 dedicated to the GW – red
•
LED3 flashes for 500ms after reset.
•
LED3 flashing in 1 s period means CDC mode (Custom Device mode is without flashing).
•
LED3 flashes 3x after clicking the IQRF logo in respective IQRF IDE (to identify the kit among other IQRF USB
devices in case of multiple IQRF IDE instances).
•
LED3 flashing in 300 ms period means missing firmware (see Software below).
•
LEDs dedicated to TR module – LED1 (red) and LED2 (green).
TR module
Wireless IQRF transceiver module compatible with TR-52B, 868 MHz as well as 916 MHz, without temperature
sensor.
Antenna
PCB antenna on GW board.
Software
Firmware for the MCU inside the GW is fixed but can be upgraded by the user using the code provided by IQRF
manufacturer. Refer to IQRF Application note
AN008 – Firmware upgrade
for details.
TR module functionality is fully user programmable. Factory default is E03-TR (one of basic IQRF examples).
Programming and uploading the code is similar to CK-USB-04.
Product information
Pack list
•
GW-USB-04
Ordering code
•
GW-USB-04
Gateway GW-USB-04, 868 MHz as well as 916 MHz
Document history
•
110929
Tip for PC CDC terminal added
•
110530
First release
© 2011 MICRORISC s.r.o.
www.iqrf.org
MNGWUSB04_ 110929