IQRF GW-USB-04 Скачать руководство пользователя страница 4

GW-USB-04

Hardware

The user can realize specific functionality by software for the TR module. Application for TR module inside can also 
be developed using the CK-USB-04 development kit. For detailed information refer to CK-USB-04 User's guide.

Power supply

GW-USB-04 is intended to be supplied via USB connector from PC.

Reset

Reset can be invoked by connecting a disconnected GW to USB or by the  

Reset USB Device  

command  in CDC 

mode.   Actual   reset   is   executed   ~5   s   after   the   command   is   issued.   This   delay   allows   to   disconnect   USB 
communication on PC side in time.

USB

The device supports two USB modes:

Custom Device mode

Full communication with the IQRF IDE is enabled in this mode. The GW uses identical USB driver like e.g. CK-
USB-04. It is possible to upload the application into internal TR module, display data received from SPI interface of 
the TR in IQRF IDE Terminal etc. The user can easily create his own PC program using the  

mpusbapi.dll 

library. See USB Custom Device Example on IQRF website.

CDC mode

After connecting to PC a virtual serial port is created in this mode. The user can create his own PC program and 
communicate via this port using the protocol described in document 

CDC implementation in IQRF platform

.

Switching between the modes:

From Custom Device to CDC: 

Using IQRF IDE v2.08 or higher: 
Help → Show IQRF USB Device Info → Switch to CDC mode.

From CDC to Custom Device: 

Using the 

Switch to USB Custom Class

 command in CDC protocol.

Current mode indication see chapter LED. The last selected mode is restored after start-up or reset.

Tip

For testing a communication in CDC mode various SW terminals operating with PC serial ports are available. Select 
a terminal enabling to issue direct byte commands and data. Refer to the communication protocol described in CDC 
Implementation in IQRF USB devices User's guide. 
Recommended terminal: Docklight, 

www.docklight.de

. There is a project containing all supported commands for 

this terminal available at 

www.iqrf.org/218

. It is necessary just to select the COM port used.

Unsuitable terminal: Windows Hyperterminal, Tera Term.

© 2011 MICRORISC s.r.o.

www.iqrf.org

MNGWUSB04_ 110929

Page 4