24
Chapter 7
– Maintenance
1.
Open the locking arms, making sure they
are fully extended outward. For details,
refer to section 6.3.
2.
Opening the arms will release the top
housing modules. Removing the dif fu ser
will reveal the HyperHEPA filter inside
Frame 3.
3.
Remove Frame 3 containing the
HyperHEPA fil ter.
5.
With the palm of the hand, press down on
the filter and loosen the frame.
4.
Turn the frame over so it is upside down.
Frame 3
Diffuser
6.6 Replacing the HyperHEPA® Filter (F3)
6.
Lift the frame from the filter.
Frame 3
HyperHEPA
filter
8.
Turn the frame over (right side up again)
and insert the new filter. Ensure that the
arrows on the filter label point upward.
The label “this way up” should be visible
when installed properly. Re-install four
filter clamps.
7.
Dispose of the used filter by placing it into
the plastic bag in which the new filter is
supplied (see section 6.7).
9.
Put frame 3 back into the housing and
reposition the diffuser. For closing refer to
section 6.3.
Frame 3
6.7 Discarding Used Filters
Used filters can normally be put into the regular household trash for
disposal. If the system may have been exposed to potentially hazardous
substances, the filters may have to be disposed of as hazardous waste.
Please refer to local regulations and laws for proper handling and disposal.
Chapter 7 – Maintenance
7.1 Cleaning the Housing
•
Unplug the IQAir system before attempting to clean it.
•
Use a soft and clean cloth for cleaning.
•
For water soluble stains, use a window cleaning fluid.
•
For the removal of tough, non water soluble stains, use a silicon spray.
•
Do
not
use any solvents or any organic cleaning fluids.
10.
After a filter has been replaced, the Filter
Life Monitor must be reset from the
control panel (see section 4.4.8).