background image

Chapter 4

– Using the Control Panel

13

timer status field

start time

stop time

4.4.3  Setting the Auto Timer

The Auto Timer Menu allows the setting of a Timer ON period, which is defined by
a START time and a STOP time. For the Timer ON period, a fan speed can be
selected in the Timer ON Fan Speed Menu (see 4.4.5). The time outside the Timer
ON period is defined as the Timer OFF period for which the air cleaner can be
switched off or for which a different fan speed can be selected in the Timer OFF
Fan Speed Menu (see 4.4.5).

The timer status field indicates whether the timer function is enabled or disabled
(on or off ). Use the time status field to quickly enable/disable the timer,  e.g. for
holiday.

1.

To reach the Auto Timer Menu from the main display window, press the 

Menu

key twice.

2.

Press and hold the 

Enter

key until the cursor starts to flash. 

3.

Press the 

p

key one time to activate the timer. 

Note: 

If the START and STOP times are identical, the timer cannot be ac tivated.

Note: 

The time is displayed in a 24 hrs. clock, military time.

4.

Press the 

Enter

key to save the timer status setting and to proceed to the

START time.

5.

Select the desired START hour by pressing the 

p

key. 

6.

Press the 

Enter

key to save the START hour and to proceed to the minute

setting. 

7.

Select the desired START minute setting by pressing the 

p

key. 

Note:

The minute settings can only be set in five minute increments.

8.

Press the 

Enter

key to save the minute setting, save the START time and to

proceed to the STOP time setting.

9.

Select the desired STOP hour by pressing the 

p

key. 

10.

Press the 

Enter

key to save the STOP hour and to proceed to the minute

setting. 

11.

Select the desired STOP minute setting by pressing the 

p

key. 

12.

Press the 

Enter

key to save the STOP minute setting, save the STOP time and

to exit the enter mode.

Note: 

The times are displayed in a 24-hour clock.

Содержание Cleanroom H 13

Страница 1: ...Cleanroom H13 User Manual Swiss Made...

Страница 2: ...nces Replacement cords are available from IQAir Only use this air cleaner for its intended purpose of air cleaning in non industrial environments Do not use this air cleaner in areas with very high co...

Страница 3: ...4 4 4 Day of the Week Timer 14 4 4 5 Timer ON OFF Fan Speed Selection Menu 14 4 4 6 Timer Information in the Control Panel 15 4 4 7 Time Day Setting 16 4 4 8 Filter Life Reset New Filter 16 4 4 9 Cha...

Страница 4: ...to cope with your room size The actual hourly air volume cleaned by the system should be at least double the air volume of your room If the rate at which pollutants enter the room air is high or the i...

Страница 5: ...tto u 4 2 m e t s y l o r t n o c e d n a t e k p o t e h t n re se e S e S C e d le o a T D D ay D e m i T Ti l a u n a m r e s u e h t o t r e f re og r p o t d e r i qu e r s i k c o cl e h t g in...

Страница 6: ...ntrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cord is positioned in a way that it does not present an obstacle in...

Страница 7: ...gn features air intake openings on two sides The Pre Filter module consists of frame 1 and the Pre Filter which is secured inside the frame by four filter clamps The fan assembly comprises two housing...

Страница 8: ...culate air HyperHEPA filter media 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 8 Chapter 3 The IQAir System s Components 3 2 Description of Removable Components...

Страница 9: ...and off Controlling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after...

Страница 10: ...or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation The faster the rotation of the fan speed LED...

Страница 11: ...et per minute x 60 air changes per hour ACH air volume of the room cu ft L x W x H Note The air delivery rates of the IQAir system at the various fan speeds settings are listed on the Technical Specif...

Страница 12: ...lter is beyond its useful life a negative number will be displayed How the Filter Life Monitor Works The basis for calculating the remaining filter life is the already elapsed operation time at the se...

Страница 13: ...rsor starts to flash 3 Press the p key one time to activate the timer Note If the START and STOP times are identical the timer cannot be activated Note The time is displayed in a 24 hrs clock military...

Страница 14: ...n and exits the enter mode 4 4 4 Day of the Week Timer The Day of the Week Timer allows the deactivation of the Timer ON period on certain days of the week In its default setting the Timer ON period i...

Страница 15: ...ng The first line shows the fan speed and the second line shows the airflow The Timer LED is off System on Standby The first line shows the current day and time and the second line shows the next time...

Страница 16: ...ter Life LED for the appropriate filter is currently flashing red 4 Press the Enter key to confirm that the selected filter has been replaced 5 To re confirm the filter change press the Enter key To e...

Страница 17: ...er mode 17 Chapter 4 Using the Control Panel 4 4 9 Changing the Airflow Units 1 You can reach the Airflow Units Menu by pressing the Menu key eight times 2 You can change the air volume units which ar...

Страница 18: ...en set in the Weekly Auto Timer Menu it is possible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch t...

Страница 19: ...r of minutes The illustration of the IQAir system on the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filters within the system...

Страница 20: ...s and push the locking arms inwards simultaneously until they snap back into the housing top of the diffuser IQ Air 20 Chapter 6 Replacing Filters Opening Closing 6 3 1 Troubleshooting When Closing th...

Страница 21: ...me from the filter 10 Make sure that the filter is inserted all the way into the frame Insert the clamps into the sliding grooves inside the frame and push them down securing the filter into place 6 5...

Страница 22: ...r at www iqair com support where you can find answers to most frequently asked questions FAQs or contact us with your inquiry To expedite your service request please have the following information rea...

Страница 23: ...ng fixture you will also need a medium size flathead screwdriver How to install the power cord fixture 1 Disconnect the power cord from the wall outlet Plug the connector of the power cord into the ai...

Страница 24: ...ng the supplied tool 7 8 6 9 Plug the red connector of the ribbon cable back into the control panel Ensure that it is pushed in all the way 10 Tuck the ribbon cable underneath and reinsert the control...

Страница 25: ...of positive pressure if placed within the room and negative pressure if placed outside the room OutFlow Complete ducting adapter kit for the creation of negative pressure if placed within the room an...

Страница 26: ...ly usage of 10h on speed 3 U S FDA registered as a Class II Medical Device Registration No 2087558 Performance 99 97 for particles 0 3 microns indiv tested at highest fan speed 99 5 at 0 003 microns y...

Страница 27: ...27 Notes...

Страница 28: ...www iqair com Swiss Made IQ_MA_CRH13_NE_US_130724...

Отзывы: