3.
Installation and connection
3.1 Notes
Theralux supplies only the heat pump itself. All other components, including a bypass if necessary, must be provided
by the user or the installer.
Attention:
Please observe the following rules when installing the heat pump:
1.
Any dosing of chemicals must take place in the piping located
downstream
from the heat pump.
2.
Install a bypass in all installations.
3.
Always place the heat pump on a solid foundation and use the included rubber mounts to avoid vibration
and noise.
4.
Always keep the heat pump upright. If the unit has been held at an angle, wait at least 24 hours before
starting the heat pump.
3.2 Heat pump location
The unit will work properly in any desired location as long as the following three items are present:
1. Fresh air
–
2. Electricity
–
3. Swimming pool filters
The unit may be installed in virtually any
outdoor
location as long as the specified minimum distances to other objects
are maintained (see drawing below). Please consult your installer for installation with an indoor pool. Installation in
a windy location does not present any problem at all, unlike the situation with a gas heater (including pilot flame
problems).
ATTENTION:
Never install the unit in a closed room with a limited air volume in which the air expelled from the unit
will be reused, or close to shrubbery that could block the air inlet. Such locations impair the continuous supply of
fresh air, resulting in reduced efficiency and possibly preventing sufficient heat output. See the drawing below for
minimum dimensions.
3.3 Distance from your swimming pool
The heat pump is normally installed within a perimeter area extending 7.5 m from the swimming pool. The greater
the distance from the pool, the greater the heat loss in the pipes. As the pipes are mostly underground, the heat loss
is low for distances up to 30 m (15 m from and to the pump; 30 m in total) unless the ground is wet or the groundwater
Содержание Theratherm 17iv
Страница 1: ...Swimming Pool Heat Pump User and Service Manual ...
Страница 2: ......
Страница 5: ...3 A Division of 2 Dimension mm Model Theratherm 17iv ...
Страница 6: ...4 A Division of Model Theratherm 30iv ...
Страница 13: ...11 A Division of Dry contact pump connection ...
Страница 14: ...12 A Division of ...
Страница 15: ...13 A Division of 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Theratherm 17iv ...
Страница 38: ...36 A Division of ...
Страница 43: ...41 A Division of 4 4 Parameter Query ...
Страница 45: ...43 A Division of ...
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ...A0141PXV01 ...