![IQ Theratherm 17iv Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/iq/theratherm-17iv/theratherm-17iv_user-and-service-manual_2089456024.webp)
22
A Division of:
For example : Tset = 28
℃
Tseting water temperature in your pool heat pump
Tset-1 = less 1
℃
than Tseting temperature
Tset- 1 = 28-1=27
℃
Tset+1= more 1
℃
than Tseting temperature
Tset+ 1 = 28+1=29
℃
6.3 Heating operation logic
Working
status
Working mode
Water in
temperature-T1
For example ,
Tset=28
℃
,
water in
temperature-T1
Heat pump working level
1
Start-up
of
heat
pump
When you
select the
"Smart
working mode "
T1< Tset-1
T1< 27
℃
Powerful mode-frequency F9
2
Tset-1
≦
T1 < Tset
27
℃≦
T1 <28
℃
Frequency
:
F9 -F8-F7,...,-F2
3
Tset
≦
T1 <Tset+ 1
28
℃≦
T1 <29
℃
Silent mode-frequency F2
4
T1
≧
Tset+1
T1
≧
29
℃
HP will be in Standby, stop
working until the water
temperature drops to less 28
℃
.
5
When you
select
the "Silent
working mode".
T1< Tset
T1< 28
℃
Smart mode -frequency F5.
6
Tset
≦
T1 < Tset+1
28
℃≦
T1 < 29
℃
Silent mode-frequency F2/F1.
7
T1
≧
Tset+1
T1
≧
29
℃
HP will be in Standby, stop
working until the water
temperature drops to less 28
℃
.
8
When you
select
the "Powerful
working mode."
T1<Tset+1
T1<29
℃
Powerful mode-frequency
F10/F9
9
T1
≧
Tset+1
T1
≧
29
℃
HP will be in Standby, stop
working until the water
temperature drops to less 28
℃
.
10
Re-start
to
heat
water in
standby
status
When HP is
working at "
Smart mode"
T1
≧
Tset
T1
≧
28
℃
Standby
11
Tset
>
T1
≧
Tset-1
28
℃
>
T1
≧
27
℃
Silent-frequency F2
12
Tset-1
>
T1
≧
Tset-2
27
℃
>
T1
≧
26
℃
Frequency
:
F2 -F3-F4,...,-F9
13
<Tset-2
<26
℃
Powerful-frequency F9
14
When HP is
working at "
Silent mode"
≧
Tset
≧
28
℃
Standby
15
Tset
>
T1
≧
Tset-1
28
℃
>
T1
≧
27
℃
Silent mode-frequency F2/F1
16
T1<Tset-1
T1<27
℃
Smart -frequency F5
17
When HP is
working at "
Powerful
mode"
T1<Tset-1
T1<27
℃
Powerful -frequency F10/F9
Содержание Theratherm 17iv
Страница 1: ...Swimming Pool Heat Pump User and Service Manual ...
Страница 2: ......
Страница 5: ...3 A Division of 2 Dimension mm Model Theratherm 17iv ...
Страница 6: ...4 A Division of Model Theratherm 30iv ...
Страница 13: ...11 A Division of Dry contact pump connection ...
Страница 14: ...12 A Division of ...
Страница 15: ...13 A Division of 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Theratherm 17iv ...
Страница 38: ...36 A Division of ...
Страница 43: ...41 A Division of 4 4 Parameter Query ...
Страница 45: ...43 A Division of ...
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ...A0141PXV01 ...