background image

*** IMPORTANT ***

As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in

England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical

system, but the work must be done in accordance with the Regulations. 

Where you employ an electrician who is a member of a competent person self-certification scheme, they

will be able to certify the work complies with the Regulations.

If you decide to carry out the work yourself we recommend that you make yourself aware of the

Regulations before you begin and if you require any clarification you should contact your Local Authority

Building Control Department.

Details of the Building Regulations can be obtained on the internet via the government website

www.odpm.gov.uk/explanatory-booklet 

MANUFACTURER'S EXTENDED WARRANTY

In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe)
Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship
which affect its designed ability to detect or switch.  During this period if the product has a defect
of this nature it will be repaired or replaced free of charge by IQ with the same item, or a similar
one of higher specification, ON CONDITION THAT:-

The buyer takes advantage of any 'return to store' scheme operated by the seller from whom it is
bought.

If the product has a defect outside the period of any seller's 'return to store' scheme it should be
returned to 

IQ (Europe) Limited at Sandbeck Lane, Wetherby, W. Yorks LS22 7TW, England

at the expense of the buyer together with evidence of the date of purchase (it is the responsibility
of the buyer to prove delivery to IQ).

The product has been bought by the user.

The product has not been misused or handled carelessly, installed incorrectly, or used on a 
voltage supply other than that shown on it.

Repairs have not been attempted by anyone other than IQ's staff.

The product has been used for domestic purposes only.

The product has not been installed in any unusually exposed or harsh environmental conditions.

If the buyer is resident in the EU the product or its replacement will be returned to the buyer at
the expense of IQ. 

This guarantee excludes liability for discolouration of paint or plastic, or any user replaceable
parts and in particular lamps, glass panels, or globes/lanterns. It does not confer any rights other
than those expressly set out above and does not cover any claims for consequential loss or 
damage. 
This guarantee is offered as an additional benefit and does not affect your statutory rights as a 
consumer.

This contract is subject to the laws of England and Wales.

SF-OEMCTV200-150&500-GR.qxd  16/05/2005  11:21  Page 2

Содержание E-636

Страница 1: ...oodlight E 636 E 638 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 V1 0 04 05 IQ OEMCTV200 150 GR IQ OEMCTV200 500 GR SF OEMCTV200 150 500 GR qxd 16 05 2005 11 21 Page 1 ...

Страница 2: ...ation ON CONDITION THAT The buyer takes advantage of any return to store scheme operated by the seller from whom it is bought If the product has a defect outside the period of any seller s return to store scheme it should be returned to IQ Europe Limited at Sandbeck Lane Wetherby W Yorks LS22 7TW England at the expense of the buyer together with evidence of the date of purchase it is the responsib...

Страница 3: ...or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful positioning of the sensor will be required to ensu...

Страница 4: ...ated onto the wall plate by two lugs which are inserted into the rectangular slots in the top of the wallplate To remove loosen but do not remove the fixing screw and lift the body of the floodlight upwards to release from the wall plate diagram F Mark the position of the fixing holes Ensure wall plate is correctly positioned Note the orientation of the wall plate diagram E Drill the holes Insert ...

Страница 5: ...ve Restrict RHS detection Restrict LHS detection Restrict long detection Restrict short detection Lens Mask Less sensitive 12m TOP VIEW SIDE VIEW 2 5m A 200º Dusk Time SF OEMCTV200 150 500 GR qxd 16 05 2005 11 21 Page 5 ...

Страница 6: ...E G UP F H wall plate fixing screw SF OEMCTV200 150 500 GR qxd 16 05 2005 11 21 Page 6 ...

Страница 7: ...light to the wall plate by locating the lugs onto into the recess on the top of the wall bracket lift the floodlight so it fits over the wall plate reverse diagram F Fully tighten the fixing screw fig E Mains Supply Isolation Switch The diagram below also shows the required connections for the addition of slave luminaires When adding slaves be sure not to exceed the maximum switchable load see Tec...

Страница 8: ...peration The TIME setting controls how long the unit remains illuminated following activation after all motion ceases The minimum time fully anti clockwise is approx 5 seconds whilst the maximum time fully clockwise is approx 5 minutes Set the control to the desired setting between these limits The DUSK control determines the level of darkness required for the unit to start operating The setting i...

Страница 9: ...e before resuming normal PIR operation Halogen Lamp Replacement CAUTION Always handle quartz halogen bulbs with a soft cloth Do not touch the bulb with your bare hand as it will shorten the life of the bulb 1 Switch off the floodlight Do not touch the Floodlight while it is in use or still hot Allow it to cool about 5 minutes before touching it 2 Replacement bulb type is 240V mains halogen 150W or...

Страница 10: ...ill not detect through glass The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details Adjust the setting anti clockwise to lower the level of ambient light required for activation Unit may be poorly located See pr...

Страница 11: ... to 40 in running costs whilst also conserving precious natural resources LIGHT POLLUTION CONSIDERATE LIGHTING Please be aware of the annoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light sprea...