18
Adjust the Clock
:
Adjust Date / Time
•
Year =
•
Month =
•
Date =
•
Day =
•
Hour =
•
Minute =
Exit the sub-menu
Adjust Time Settings
•
Maximum Run Timer = adjustable from 10 to 180 seconds, this timer amount represents the maximum
number of seconds that the gate operator can run in one direction
•
Close Delay Timer = adjustable from OFF to 4:15, this timer represents the amount of time from OFF to
seconds to minutes of how long the gate waits to close from the open limit after all open and hold open
inputs are removed
•
Holiday Next ____ thru ____ (adjustable up to 8 days in advanced) This option is to be used to define
what day of the week an upcoming holiday is (if it is desired that the gate not open with the 7-day open
timer on that holiday) Just enter the first day of the holiday and the last day of the holiday.
•
7-day open timer = (Completely Off, Off to next {next on program}, On) this is the option in which the 7-
day open timer could be activated
•
P-1 Open @ 08:00am / Su Mo Tu We Th Fr Sa
(These P-* options are the programmable 7 day auto open timers. You can choose the time and days that the
gates automatically open and then close. There are 4 available auto open time slots. To program, adjust the
desired time and then display what days you would like the timer to function. If a day is undesired, move the
cursor under that day and press the programming knob to erase that day from the program. Then scroll
clockwise and set the days and time for the auto close). Here is an example of the 7-day open timer:
•
7Day Security Timer = (Completely Off, Off to next {next on program}, On)
(The security timer has 2 available time slots that can be programmed for desired days and times to allow or
secure 5 inputs. The inputs that can be secured are: Open, Exit, Radio Terminal, AUX IN 1 and AUX IN 2. To
program a secured input, simply program the desired time and the days to secure that input, and also when to
release. Then allow the inputs by scrolling to “Secure Inputs, Allow” screen and move the cursor under a
desired input. To secure that input, press the programming knob. The inputs that remain displayed will be
allowed during the Secured Input timer.
•
Secure Inputs, Allow = Open, Exit, Radio Terminal, Aux In 1 and Aux In 2
Exit the sub-menu
P-1 Open: 07:00a
Su Mo Tu We Th Fr Sa
P-1 Secure at 5:30p
Su Mo Tu We Th Fr Sa
Secured inputs
Open-Exit-RadioTerm-Aux1-
Aux 2
Содержание IntelliSlide IQ-5000
Страница 12: ...12 ...
Страница 15: ...15 12 24 VDC Power Input Terminals Inductance Loop Terminals Input Power Ground Terminals ...