background image

Product Description of BRT-304C

Page 2 of 5

Shenzhen Asia Bright Industry co., Ltd., Building 10, Asia Industrial Park, Gangtou, Bantian, Shenzhen, China.

www.a-brt.com

[email protected].

© 2015 All rights reserved. Subject to change without notices.

Specification Parameters:

Input Voltage

220

240V(50Hz/60Hz)

Operation

Environment

No-condensation 20-90% RH

-20

℃~

40

Wattage

800W

Working

Range

Up to 5m in a cone of 120

degrees

Mounting Hole

Spacing

60mm

Matching

Box

75mm x 75mm x 50mm

Dimension

86mm x 86mm x 43mm

Weight

72g

Wiring Diagram and Installation Guide:

BRT-304C occupancy sensor switch require both hot wire and neutral wire for installation:

Hot wire (ACL):

Coming from the power line with 220V;

Neutral wire (ACN):

Usually coming with the hot wire; and

Load wires:

Going to the load.

Fig. 3

BRT-304C Wiring Diagram

Warning:

Please make sure power is turned off before starting installation!

Fig. 3 shows the wiring diagram and Fig. 4 shows the step-by-step installation instructions. There

are three easy steps:

Step one:

Use a screwdriver to pry off the front plate in position A;

Step two:

Wiring according to the diagram and the labelled ports of the switch; and

Step three: Install screws and front plate.

Содержание BRT-304C

Страница 1: ...ce is occupied and turns on or turns off the loads automatically It is designed for easy installation and retrofit directly fit into standard wall box where both hot wire and neutral wire are present Load power up to 800W Adjustable delay off time from 10 seconds to 15 minutes Ambient light override Automatically measures the ambient light level and there is no trigger on above a light level adjus...

Страница 2: ... 43mm Weight 72g Wiring Diagram and Installation Guide BRT 304C occupancy sensor switch require both hot wire and neutral wire for installation Hot wire ACL Coming from the power line with 220V Neutral wire ACN Usually coming with the hot wire and Load wires Going to the load Fig 3 BRT 304C Wiring Diagram Warning Please make sure power is turned off before starting installation Fig 3 shows the wir...

Страница 3: ...nt on off switch or appliance as those on off actions could cause false triggers BRT 304C Operation Guide BRT 304C PIR sensor switch needs a warm up time about two minutes before it can operate properly It has a precision tuning screw to adjust the ambient light override threshold as shown in Fib 5 and another precision tuning screw to adjust the delay off time as shown in Fib 6 1 Adjust the ambie...

Страница 4: ...kwise to decrease the threshold so that the PIR triggers will not be overridden in dark lighting condition Fig 5 Adjustment of Ambient Light Override Threshold 2 Adjust the delay off time There is another tuning screw on another side of BRT 315 PIR sensor switch Use a screw driver to tune this screw to adjust the delay off time as shown in Fig 7 The delay off time can be set from 10s to 15 minutes...

Страница 5: ...ds of electrical equipment especially good for high power loads BRT 304C PIR occupancy sensor switch is perfect for saving energy and bringing convenience and safety to our daily life and work It has wide applications at various locations such as stairwells corridors washrooms offices conference rooms in homes schools laboratories hospitals offices etc How to Order Please contact us Shenzhen Asia ...

Отзывы: