![IPSO PC30 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ipso/pc30/pc30_re-programming-manual_2089350042.webp)
43
Interruption and stopping the program
When the " STOP " button is briefly pressed , the text of the display flashes and after 5 seconds the machine
starts to drain the water (that is if an emergency stop "
EMEr
" was selected in the "preprogram").
The buzzer starts working after 30 seconds and "
oPEn door
" will appear and the door should be opened. Then
"
CLoSE
" appears.
After closing the door again you can:
-
continue the program
by pressing " START "
-
cancel the program
by pressing " STOP ".
The stop function has a delay of 60 seconds during spin 1 and a delay of 120 seconds during spin 2.
Adding water (not with coin-op version)
If you press one of the buttons from " 1 " to " 8 " during a program, the corresponding water inlet valve is opened.
While pressing this button, the number of the selected inlet valve and the level is shown in
"
iX LXX
". This information is displayed for 3 seconds after the button is released.
This function does not work during the first
3 minutes
of a program.
Draining water (not with coin-op version)
When you press button " 9 " during a program, drain valve " D1 " is opened.
When you press button " 0 " during a program, drain valve " D2 " is opened.
While pressing this button, the number of the selected drain valve and the level is shown in "
dX LXX
". This
information is displayed for 3 seconds after the button is released.
This function does not work during the first
3 minutes
of a program.
Heating the bath
By keeping the button " +10 " depressed during a program, the heating is activated. (Max. 95°C).
While pressing this button, the temperature of the bath is shown with "
°C XX
" (or "
°F XX
").
This function does not work during the first
3 minutes
of a program.
Time Stop
(not on the coin version)
By keeping pressing the STOP button for more than 3 seconds, the program will go into
time stop
(only
if
EMEr
was selected in the preprogramming mode)
This can be used to e.g. extend a program segment in case of heavily soiled linen. The time will be stopped and
the step currently activated will be preformed indefinitely. The programmed water level and temperature will
be kept constant. During the time stop the display shows
XX.tistop
.
Now, the stop time can be entered if so desired. Press E to confirm.
The display now shows
XX.ti XXX
. Enter the desired stop time using X,X,X
(between 1 and 999 minutes)
and press "E " again. The display will now alternately show
StoP.tiME
and the remaining stop time counting
down. After the stop time has elapsed, the program will resume automatically.
If no stop time was selected, the stop time will be indefinite until the START button is pressed again.
A " time stop " during the final spin will be automatically interrupted after
20 minutes
.
Operating mode
6
Содержание PC30
Страница 7: ...8 ...
Страница 9: ...10 ...
Страница 11: ...12 ...
Страница 13: ...14 ...
Страница 15: ...16 ...
Страница 17: ...18 ...
Страница 19: ...20 ...
Страница 21: ...22 ...
Страница 23: ...24 ...
Страница 25: ...26 ...
Страница 27: ...28 ...
Страница 29: ...30 ...
Страница 31: ...32 ...
Страница 33: ......
Страница 35: ......
Страница 37: ......
Страница 44: ...45 ...