25
4
WATER MIX TIME:
The 20 is equipped with a controlled water mix system through which the bath
temperature is approached as much as possible. As a result, in most cases, no
extra heating (or only a minimum) is necessary.
The information to make this mix can be programmed here.
If you do not want to use this mix system : proceed by means of the cursor control
keys to
“OPTIONS”
, if mix is wished :
T1
appears and behind it a white text block.
This is the
filling time
. During this time the
programmed
water inlets will be
opened.
the number of seconds of this action.
to confirm.
T2
appears and behind it a white text block.
Gedurende This is the
mix time
. During this time, no water is added.
Through the movement of the drum, the water is well mixed.
Here, “0” can as well be filled in.
the number of seconds of this action
to confirm.
T3
appears and behind it a white text block.
This is the
correction time
. During this time, after comparison with the required
temperature, cold or warm water will be added.
the number of seconds of this action.
to confirm.
press
press
type
press
type
press
type
Standard Times
lower then 30 °C
from 30 °C
T1
5s
5s
T2
5s
0s
T3
5s
2s
Remark: