© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
5-08-51
55
Installation
Models IWF014, IWF018, IWF025 and
IWF030 (M-speed)
Surface
The machine must be securely fixed on a flat surface
(metal base, concrete or solid ground). The anchoring
is to be done on the 6 provided places in the holes on
the corners of the base. (See Mounting Bolt Hole
Locations). Refer to
Figure 32
.
Figure 32
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
Anchoring to Metal Base
The machines must be fixed on a metal base which is
securely anchored on a concrete base. Refer to
Figure 33
.
Figure 33
CHM2102N
1
Mounting Bolt Holes
Ensure that the machine is installed on a
level floor of sufficient strength and that
the recommended clearances for
inspection and maintenance are provided.
Never allow the inspection and
maintenance space to be blocked.
SW020
CAUTION
CHM2102N
1
CHM2103N
1
Machine Base
2
Nut
.5 in. (M12) (Models IWF014, IWF018 and
IWF025), .625 in. (M16) (Model IWF030)
3
Washer
1.57 in. x 0.60 in. x 0.15 in.
(40 mm x 17 mm x 4 mm)
4
Bolt
.625 in. x 2.5 in. (M16x60 mm)
5
Bolt
.5 in. (M12) (Models IWF014, IWF018 and
IWF025), and .625 in. (M16) (Model IWF030)
6
Concrete Base
9.48 in. (250 mm) (Models IWF014, IWF018
and IWF025), and 13.77 in. (350 mm)
(Model IWF030)
7
Metal Base
CHM2103N
1
2
3
7
4
6
2
3
5