连接接口
Specification
Item
Description
Power
Power
Supply
Power
Adapter
Voltage
range
DC12V~24V
Consumption
<
3W
Ethernet Port
parameter
Ethernet Port
Ethernet
port
:
10
/
100
/
1000Mbps
Transmission Distance
:0
~
150m
Ethernet
port
Fiber Port
parameter
Fiber Port
LC Port, SFP
Optical
Module, Single Fiber or Dual
Bandwidth
1
.
25Gbps
Transmission Distance
Depend on SFP module performance
network
exchange
specifiction
Ethernet
standard
IEEE802
.
3
、
IEEE802
.
3u
、
IEEE802
.
3ab
/
z
、
10
/
100
/
1000BASE
-
TX and 1000BASE
-
FX
、
IEEE802
.
3
X.
Status
indicator
Power indicator light
1
Red
Network indicator light
1 Green on
RJ45 Socket
Fiber indicator light
3
Green (Link,SD,FED)
Protection
level
ESD
3
level,Standard:IEC61000
-
4
-
2
Protection level
3
level,Standard:
IEC61000
-
4
-
5
Operation
environment
Working Temperature
0
~55
℃
℃
Storage Temperature
-
40
~85
℃
℃
Humidity (non-condensing)
0~95
%
Mechanical
Dimension (L×W×H)
26mm×71mm×94mm
Material
Aluminum Alloy
Color
Black
Weight
160g
Product
are
subject
to
change
without
prior
notice
Gigabit Ethernet Converter
3
4
Gigabit Ethernet Converter
连接接口
连接接口
Trouble Shooting
Please find the following solution when the device doesn't work
Please confirm if the installation is correct;
Please confirm if the RJ45 cable order is in accordance with the EIA/TIA568A or 568B industry
standards;
The maximum transmission distance depends on the signal source and cable quality, please do not
exceed the maximum transmission distance;
Please replace a failure device with a normally working device to check if the device is broken;
If the problem still exists, please contact the factory.
Instruments to be used: wire
crimper, network tester.
Wire sequence
of
RJ45
plug should conforms with EIA/TIA568A or 568B standards.
1) Shuck off about 2cm long of the insulating layer to expose the 4 pairs UTP cables;
2) Seperate the 4 pairs UTP cables and straighten them up;
3) Line up the 8 pieces of cables per EIA/TIA 568A or 568B standards;
4) Brunt cut the cables to leave 1.5cm wire exposed and make sure the wire ends are leveled off;
5) Plug 8 cables into RJ45 plug, make sure each cable is in each pin;
6)Then use wire crimper to crimp it;
7) Repeat above 5 steps to make the another end;
8) Using network tester to test the cable .
RJ 45 Making Method
Make sure if one end is EIA/TIA568B,the other end should also be EIA/TIA568B.
Make sure if one end is EIA/TIA568A,the other end should also be EIA/TIA568A.
p
in color
white/green
green
blue
white/orange
white/blue
white/brown
orange
brown
1
2
3
4
5
6
7
8
pin color
1
2
3
4
5
6
7
8
white/green
green
blue
white/orange
white/blue
white/brown
orange
brown
EIA/TIA 568A
EIA/TIA 568B
Notice