background image

连接接口

Specification

Item

Description

Power

Power

 

Supply

Power

 

Adapter

Voltage

 

range

DC12V~24V

Consumption

3W

Ethernet Port 

parameter

Ethernet Port

Ethernet

 

port

:

10

/

100

/

1000Mbps

Transmission Distance

 

:0

150m

Ethernet

 

port

Fiber Port 

parameter

Fiber Port

LC Port, SFP

 

Optical

 

Module, Single Fiber or Dual 

Bandwidth

1

.

25Gbps

Transmission Distance

Depend on SFP module performance

network 

exchange 

specifiction

Ethernet

 

standard

IEEE802

.

3

IEEE802

.

3u

IEEE802

.

3ab

/

z

 

10

/

100

/

1000BASE

-

TX and 1000BASE

-

FX

IEEE802

.

3

 

X.

Status

 

indicator

Power indicator light 

1

 

Red

Network indicator light

1 Green on

 

RJ45 Socket

Fiber indicator light

3

 

Green (Link,SD,FED)

Protection

 

level

ESD

3

 

level,Standard:IEC61000

-

4

-

2

Protection level

3

 

level,Standard:

 

IEC61000

-

4

-

5

Operation

 

environment

Working Temperature

0

~55

Storage Temperature

-

40

~85

Humidity (non-condensing)

0~95

%

Mechanical

Dimension (L×W×H)

26mm×71mm×94mm

Material

Aluminum Alloy

Color

Black

Weight

160g

Product

 

are

 

subject

 

to

 

change

 

without

 

prior

 

notice

Gigabit Ethernet Converter

3

4

Gigabit Ethernet Converter

连接接口

连接接口

Trouble Shooting

Please find the following solution when the device doesn't work

Please confirm if the installation is correct;

Please confirm if the RJ45 cable order is in accordance with the EIA/TIA568A or 568B industry 

standards;

The maximum transmission distance depends on the signal source and cable quality, please do not 

exceed the maximum transmission distance;

Please replace a failure device with a normally working  device to check if the device is broken;

If the problem still exists, please contact the factory. 

Instruments to be used: wire

 

crimper, network tester.

Wire sequence

 

of

 

RJ45

 

plug should conforms with EIA/TIA568A or 568B standards.

1) Shuck off about 2cm long of the  insulating layer to expose  the 4 pairs UTP cables;

2) Seperate the 4 pairs UTP cables and straighten them up;

3) Line up the 8 pieces of cables per EIA/TIA 568A or 568B standards;

4) Brunt cut the cables to leave 1.5cm  wire exposed and make sure the wire ends are leveled off;

5) Plug 8 cables into RJ45 plug, make sure each cable is in each pin;

6)Then use wire crimper to crimp it;

7) Repeat above 5 steps to make the another end;

8) Using network tester to test the cable .

RJ 45 Making Method

Make sure if one end is EIA/TIA568B,the other end should also be EIA/TIA568B.

Make sure if one end is EIA/TIA568A,the other end should also be EIA/TIA568A.

   

p

in color

   

           

white/green

                 

green

                    

blue

              

 white/orange

                

white/blue

                white/brown

                    

orange

         

    brown

1

2

3

4

5

6

7

8

 

pin color

1

2

3

4

5

6

7

8

   

           white/green

                   

green

                   blue

               white/orange

                white/blue

                white/brown

                    

orange

                   

brown

EIA/TIA 568A

EIA/TIA 568B

Notice

Отзывы: