APPENDIX B: IP8B TEST DATA SHEET
369548.DOC
Page
23
Data Quality
Parameter Spec Measured
Receiver 1 Data Quality
(x=1400, 19 Command
IP
Message Utility)
240>
Receiver 2 Data Quality
(x=1400, 19 Command
IP
Message Utility)
240>
Receiver 3 Data Quality
(x=1400, 19 Command
IP
Message Utility)
240>
Exciter
Parameter Spec Measured
Transmit Frequency Error
(Transmitting 1400 character test message)
+/- 500 Hz
Transmit Modulation Deviation
(5.3 kHz while transmitting 1400 character test
message)
5.1 kHz to 5.3 kHz
Transmit Data Quality
(While transmitting 1400 character test message
to the base station)
240>
Transmit Power Control
Warning: Do Not exceed 20 Watts RF output power during this test
Parameter Spec RF
Out
RF Out Max
Level set to
Output Power
(Use x=1400,19 command)
20 +/- 1 Watt
Test Check List
Test Task
Completed
(
9
)
Attached copy of Base Station’s Firmware Settings
Visual Inspection
Copy Base Station Settings Below: