2.1. Press “
SET
” button, and power on the controller, enter the parameter setting and other
function interface, as how in figure 1.
2.2. Press “
MODE
” button to move the arrow to select
“
WRITE ADDRESS
”
as shown in the
figure.
2.3. Press “
SET
” button to select “
WRITE ADDRESS
”
,
enter into address writing mode interfac, as
show in the figure:
①.
START CH:
Start channel
(
The starting address is set in the range of 0-512,
and the regular is 001.
)
②.
CH MODE:
Interval channel
(
Interval channel setting in the range of 0-255
)
③.
IC
:
Chip model
(
Rfer to DMX512 IC list
)
④.
PORT NUM:
Address port
(
Refer to the port list
)
⑤.
RETURN
Return to the main interface
2.4. Press the
“
MODE
”
button to move the corresponding item of the arrow, and press
“
SPEED+
”
and
“
SPEED-
”
to set the start channel/interval channel/IC option/address port
respectively.
1.DMX512 IC list
UCS512A*/B*,TM512AL1/AB WS2821
DMX512AP
UCS512C*
,
TM512AC*
SM1651*-3
SM1651*-4
UCS512D*/TM512AD
*
UCS512-E
SM17512*
SM17522*
UCS512-F
TM512AC*
GS8512
SM17500
2. port code list
1
Port OUT1
5
Port OUT5
2
portOUT2
6
Port OUT6
3
Port OUT3
7
Port OUT7
4
Port OUT4
8
Port OUT8
ALL
All ports OUT1-8
NOTE: the contorller supports all ports write address, also supports single port write