1. Teach-in of the measuring range
2. Changing the output function
(4 … 20mA – 0 … 10V)
3. LED display after each teach
process
Master-/slave function
With the help of this function, up to 10 sensors of the same type can be operated in parallel.
To do this, configure the devices accordingly via IO-Link. Define one sensor as the master and all
others as slaves. The master must be assigned the highest number in the network.
Then connect the black wires (PIN 4) with each other (see connection diagram).
The following operating modes can be selected:
1. Synchronous operation: The transmission pulse of all sensors occurs simultaneously with
synchronized evaluation. Select this function for monitoring large
areas.
2. Multiplex operation:
The transmission pulses of the sensors are time-delayed in a
defined sequence. The devices can thus no longer influence each
other, smaller distances between them are possible
Note:
Resetting to the factory setting is only possible via IO-Link.