1.  Teach-in of the measuring range

 

 

 

 

 

 

 

 

2.   Changing the output function  
      (4 … 20mA – 0 … 10V)  
 

 

 

 

 

 

 

 

 

 

3.   LED display after each teach 

process 

 

 

 

 

 

 

 

 

 

 

 

Master-/slave function 

With the help of this function, up to 10 sensors of the same type can be operated in parallel. 
To do this, configure the devices accordingly via IO-Link. Define one sensor as the master and all 

others as slaves. The master must be assigned the highest number in the network. 
Then connect the black wires (PIN 4) with each other (see connection diagram). 
The following operating modes can be selected: 
1.   Synchronous operation:   The transmission pulse of all sensors occurs simultaneously with 

synchronized evaluation. Select this function for monitoring large 

areas. 

 2.  Multiplex operation: 

The transmission pulses of the sensors are time-delayed in a 

 

 

 

 

defined sequence. The devices can thus no longer influence each 

 

 

 

 

other, smaller distances between them are possible

 

 

 

 

 

 

Note: 

Resetting to the factory setting is only possible via IO-Link.

 

 

 