background image

Attention! 

Do not expose the system to magnetic fields. Any direct contact of the 

magnetic strip with magnetic fields (e.g. adhesive magnets or other permanent 

magnets) is to be avoided. Sensor movements during power loss are not cap-

tured by the follower electronics. 

Mounting examples 
Mounting with chamfered ends (fig. 2) is not recommended unless the strip is installed in a safe 

and  protected  place  without  environmental  influences.  In  less  protected  mounting  places 

the strip may peel. There we recommend mounting accord. to fig. 3 and 4. 
Mounting in a groove (fig. 5) best protects the magnetic strip. The groove should be deep enough 

to totally embed the magnetic strip. 

MANUAL

 • Subject to alteration! Version: 

Juli 2016

 

ipf electronic gmbh

 • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 • Fax +49 2351 9365-19 

 [email protected] • 

www.ipf-electronic.com 

3

 

Содержание MW11 Series

Страница 1: ...ings and information which are marked either directly on the device or specified in this document Warranty can only be claimed for components supplied by ipf electronic gmbh If the sys tem is used tog...

Страница 2: ...between 20 C to 30 C and in dry atmosphere Advice When applying long pieces of magnetic strip do not immediately remove the com plete protective foil but rather peel back a short part from the end suf...

Страница 3: ...ecommended unless the strip is installed in a safe and protected place without environmental influences In less protected mounting places the strip may peel There we recommend mounting accord to fig 3...

Страница 4: ...de ten sion relief and drag chain or casing if necessary Observe the correct alignment with regard to the counting direction fig 6 This does not apply if the counting direction can be reversed in the...

Страница 5: ...screen and ground 0V must be star shaped and across an extensive area Ensure that the connection of the screen and earth is made to a large surface area with a sound connection to minimise impedance T...

Страница 6: ...c sensor and magnetic strip not observed over the total travel distance Sensor touches strip see fig 6 Cable squeezed interrupted cut by sharp edges Sensor s active side not mounted towards the magnet...

Страница 7: ...netic strip AM000059 MANUAL Subject to alteration Version Juli 2016 ipf electronic gmbh Rosmarter Allee 14 58762 Altena Tel 49 2351 9365 0 Fax 49 2351 9365 19 info ipf electronic com www ipf electroni...

Страница 8: ...use these devices in applications where the safety of a person depends on their functionality MANUAL Subject to alteration Version Juli 2016 ipf electronic gmbh Rosmarter Allee 14 58762 Altena Tel 49...

Отзывы: