factory settings
OU 1
SP.rP
OU 2
4 … 20
SP 1
50% of nominal pressure
rP 1
10% of nominal pressure
SP 2
75% of nominal pressure
rP 2
10% of nominal pressure
T
echnical
D
ata
pressure range [bar]
excess pressure [bar]
pressure detection
operating voltage U
B
voltage drop
current consumption
switching outputs
time delay
adjustment range switch-
point release position
sampling frequency
repeatability
current output
burden
voltage output
burden
error recognition
rise time
damping
linearity deviation system
pressure display
switching function display
display damping
operating temperature
temperature drift
conn. to pressure system
sensor head material
housing material
degree
of protection
electrical connection
optical interface
see list of articles
150% of nominal pressure (P
N
)
peak value memory every 2msec (display via PC)
12 ... 32V DC, reverse polarity protection
(15 ... 32V DC, if operated with voltage output)
< 2V
< 60mA
2 x pnp-switching, no/nc, 1A short-circuit protection
0 to 20sec, on-/off-delay adjustable separately
1 ... 100% of PN,
0 ... 99% of PN
max. 125Hz
< ±0.1% of accumulated value
0/4 ... 20mA, 20 ... 0/4mA, start- and end-point selectable max. R
L
max. RL [Ω] = (UB-8V) / 20mA
0 ... 5/10V, 5/10 ... 0V, start- and end point selectable
min. 5kΩ
anal
og
outp
.
if
line breakage
(current) - short-circuit (voltage, ≥1V)
5msec (10% ... 90% of P
N
)
0 ... 20sec, adjustable
max. ±0.25% of P
N
4 x 7 segment LED-
d
isplay
2x LED red
0 ... 20sec, adjustable
-20°C ... +80°C
< ±0.2% / 10K (-10°C ... +70°C)
G1/2A, SW 27
stainless steel 1.4435
PA6.6, polyester
IP65
acc.
EN 60529
M12 connector
,
8
-pin
9600 Bau
d
, via op
to-
adapter
on
USB-Port
optical interface
9600 Baud, via optical adapter at USB-port