background image

ww

w

.ip

el

ec

tr

on

ix

.c

om

 

 IPEX 

(IP Electronix)

               

PH232Ex2

User’s Manual

 

 

Page 15 of 28 

                                                                          Doc No.: PH232Ex2-UM-001  

                                                                                                                                                            14 January 2022 

-

 

Device Information Webpage 

 

You can see some general information about the device such as MAC address, Firmware and Hardware 
version and … in this page. 
 

 

 

 

Содержание PH232E-2 Series

Страница 1: ...Doc No PH232Ex2 UM 001 IPEX IP Electronix 14 January 2022 USER S MANUAL PH232Ex2 2 RS 232 OVER ETHERNET TERMINAL SERVER CLIENT...

Страница 2: ...www ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 2 of 28 Doc No PH232Ex2 UM 001 14 January 2022...

Страница 3: ...TTOM VIEW 6 6 FRONT VIEW 6 7 BACK VIEW 6 8 GENERAL INDICATORS 7 9 PORT INDICATORS 7 10 DEVICE POWER SUPPLY 7 11 RS 232 SERIAL PORTS PIN CONFIGURATION 8 12 RS 232 CONNECTING METHODS 9 13 CONNECTION DIA...

Страница 4: ...EMI is implemented in its design and it has 3kV insulation between Ethernet and RS 232 sides Furthermore all the RS 232 ports are insulated from each other too 2 SPECIFICATIONS Number of Ports 2 RS 2...

Страница 5: ...stalling the PH232Ex2 verify that the package contains the following items 1 1 PH232Ex2 Multiport 2 1 Quick Start Guide 3 1 Document and Driver CD ROM 4 2 DB9 Female Connector 5 1 220V AC to 12V DC Ad...

Страница 6: ...www ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 6 of 28 Doc No PH232Ex2 UM 001 14 January 2022 4 TOP VIEW 5 BOTTOM VIEW 6 FRONT VIEW 7 BACK VIEW...

Страница 7: ...s on continuously UDP LED Green Blinking this LED shows that the UDP mode for this port is selected and device is trying to connect in this mode If the network works properly then this LED turns on co...

Страница 8: ...www ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 8 of 28 Doc No PH232Ex2 UM 001 14 January 2022 11 RS 232 SERIAL PORTS PIN CONFIGURATION...

Страница 9: ...or other DCE devices DB9 Female Pin Number PH232Ex2 Port as DTE DB9 Male Pin Number Pin 1 DCD Output Pin 1 DCD Input Pin 2 RxD Output Pin 2 RxD Input Pin 3 TxD Input Pin 3 TxD Output Pin 4 DTR Input...

Страница 10: ...er DTE devices DB9 Male Pin Number PH232Ex2 Port as DTE DB9 Male Pin Number Pin 7 RTS Output Pin 1 DCD Input Pin 3 TxD Output Pin 2 RxD Input Pin 2 RxD Input Pin 3 TxD Output Pin 6 DSR Input Pin 4 DTR...

Страница 11: ...22 Simple Null Modem Connection to PC PLC Without Hardware Flow control PC PLC or other DTE devices DB9 Male Pin Number PH232Ex2 Port as DTE DB9 Male Pin Number Pin 3 TxD Output Pin 2 RxD Input Pin 2...

Страница 12: ...ort of the PH232Ex2 then you can connect to the device behind the network by any application software you want by opening a TCP or UDP Socket without need of any auxiliary driver Any Device with a RS...

Страница 13: ...ch other so RS 232 PORT of Server connects to RS 232 PORT of Client via network Now you can connect your RS 232 devices to COM Ports as shown in the following diagram Any Device with a RS 232 Port for...

Страница 14: ...n device configuration webpage enter the device IP on your web browser address bar like this figure The device Default IP Address is 192 168 1 100 and the default Subnet Mask is 255 255 255 0 Now ente...

Страница 15: ...ctronix PH232Ex2 User s Manual Page 15 of 28 Doc No PH232Ex2 UM 001 14 January 2022 Device Information Webpage You can see some general information about the device such as MAC address Firmware and Ha...

Страница 16: ...w ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 16 of 28 Doc No PH232Ex2 UM 001 14 January 2022 Security You can change device configuration webpage user name and password in this pa...

Страница 17: ...2022 Network Settings You can change all the network settings such as device IP Address in this page It is important to enter valid data in this section If you are not sure about your network settings...

Страница 18: ...www ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 18 of 28 Doc No PH232Ex2 UM 001 14 January 2022 PORT Settings You can see and change all the port settings in this page...

Страница 19: ...www ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 19 of 28 Doc No PH232Ex2 UM 001 14 January 2022 Pinout Guide RS 232 Port pinout is seen in this page...

Страница 20: ...CE If you change the device IP and forget it you can see the new IP Address on the serial port Whenever you turn on the device it sends its IP Address and Subnet Mask to the RS 232 PORT1 The ports set...

Страница 21: ...everything is set properly the green and yellow LEDs on the PH232Ex2 s RJ45 socket will blink Now it is important to check the network wiring topology and testing all the cables routers switches in t...

Страница 22: ...14 January 2022 Now you should see the ping response from the device If there are any problems in the network you could not see response from the device If you see this timeout window you can t contin...

Страница 23: ...port numbers are as follow Port 1 9761 Port 2 9762 For example we connect to Port 1 by means of Hyper Terminal Run Hyperterm exe and from properties dialog box select TCP IP Winsock Enter device IP Ad...

Страница 24: ...www ipelectronix com IPEX IP Electronix PH232Ex2 User s Manual Page 24 of 28 Doc No PH232Ex2 UM 001 14 January 2022...

Страница 25: ...Switch If one serial port is redirected to itself you have a LOOP line that is very useful for testing a communication line There are two ways to set redirect for each port setting in main configurat...

Страница 26: ...irect command from a remote workstation or software to device we need IP number or Host Name and the UDP port number The default UDP port number is 9765 and you can change this port number if necessar...

Страница 27: ...a binary value from 0x00 to 0x03 for PORT1 to PORT4 status Redirect Status Byte as follow X X X X P4 P3 P2 P1 X Don t Care P i 1 means redirect to this port i is enabled P i 0 means redirect to this...

Страница 28: ...ARANTEE All products manufactured by IPEX are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser 20 TECHNICAL SUPPORT If you have...

Отзывы: