21
Generic Keyswitch Programming
Keyswitch state programming examples for Ademco, Digital
Security Controls, and GE NetworX for Keyswitch and panel state
program output operations are given below.
Most alarm panel manufacturers will have the capability to
configure a zone as a keyswitch and generally have at least one
on-board programmable output that can be configured to activate
on a number of different control state conditions. Reference the
alarm panel installation manual for details on your specific
installation.
Ademco (General Concept)
56 program zone as type 77
80 Menu LED Outs
Program 17 and 18 zone type 78 and 79
DSC PowerSeries (General Concept)
Program zone as '22'
PGM Output '6'
DSC Alexor (General Concept)
Wiring:
Y/Tx -> I/01
G/Rx -> I/02
6.2k ohms resistor from + -> Y/Tx
Programming:
Section 009 - '06'/'22'
Section 013 - Enable 2 & Disable 1
Section 134 - Enable 14 (Press 9, then 6) This makes it normally
closed.
Section 501 - Enable 3
GE NetworX (General Concept)
Program zone as '11'
LED Status
Location 47 Segment 1: 21
Location 47 Segment 2: 0