- 9 -
reset button with a sharpen pin for
10 seconds then release. There are THREE beeps
response ( short
–- mid long – short ) which means
reset successfully and 9820MT will be rebooted itself
( one beep after reboot ) and most information go back
to default setting .
Temp :
This is the Temperature Sensor ( RED , on board ) to
detect the temperature around of 9820 .
The detect range is -20 ~ 70
℃
/ - 4 ~ 158
℉
.
IR :
This area is for receiving the signal from handheld IR
remote controller
DI :
Dry Contact
Power Light :
Device power .
DC 12V Out
Supply DC 12V 1A power.
LCD Display :
Show the IP address , Temperature, Voltage and
current of each port .
Rear View
From Left side to Right side
Power Inlet :
100~240 VAC & 50~60HZ , IEC320 C20.
Power Switch:
The Power switch turns on the input power.
Breaker Reset :
This is Fuse protection to prevent electrical surges
from damaging the unit. The 9820MT comes with one
spare fuse in the unit.
8 Outputs:
9820MT-S : IEC 320 C13 .