IP POWER 9212 USER MANUAL
9. FAQ
Q1
: I forgot the password and can not enter the administration page now, what can I do?
A1
: Turn on the power normally, and then click the ipedit.exe program to enter the web page.
Type in the username “superuser” and press ok then press the reset button in 9200; it will back to
the default settings. Now you can enter the administration page.
Q2
: I cannot open the IE web page, why?
A2
: Please update your IE or use the up-to-date version of Netscape browser.
Q3
: Why the on/off operation can work immediately?
A3
: if you operate the IP Sensor 9201 in Ethernet, the operation will work immediately. If you
operate it through the Internet, the response speed depends on the situation of the network.
Normally the delay is not obvious because the date need to be transported during operating the
IP Sensor 9201 is very little.
10. Control and Settings Through HTTP Command
User can control the 9212’s action directly though the HTTP orders.
The format of the HTTP order is:
http://username:
[email protected]/Set.cmd?CMD=***Power+para1=*+para2=*+para3=*
……
Explanations of each part of the order:
Username: 9212’s username, default username is
admin
Password: 9212’s password, default password is
12345678
XXX.XXX.XXX.XXX
the IP Address of 9212
CMD=***Power: the function module of 9212
para1 ~ para3 parameters
Example 1
: control the power supply of 9212:
http://admin:[email protected] /Set.cmd?CMD=S
P60=1+P61=1+P62=1+P63=0
This command control IP Power 9212 IP address at 192.168.1.0, user name is
admin
and
password is
12345678
.
This order will:
turn on the power of outlet1 (p60); turn on the power of outlet2 (p61),
turn on the power of outlet3 (p62); turn off the power of outlet4 (p63).
When this order is sent, the IP Power will return the following message:
<html>P60=1,P61=1,P62=1,P63=0</html>
* Function of 9212:
1. SetPower : to control I/O - read parameter as follow
VER. X.X,
- 33 -