9
ADJUSTING TEMPERATURE IN SINGLE-TEMPERATURE CABINETS
How to visualise and modify programmed temperatures
(see symbol key)
Keeping key 4 (SET) pressed down, the message SP1 will appear (indicates that you have en-
tered into setting phase).
Press key 4 (SET) again and the set temperature will appear.
Modify programmed temperature pressing keys 2 and 3 ( ▲▼).
Press key 4 (SET) again to confirm.
Directions
The inside temperature will appear on the display (5).
The green indicator light (6) will switch on to indicate that the refrigeration system is in oper-
ation (part of normal meat cellar operation).
The red indicator light (8) will switch on to indicate that the heating system is in operation
(part of normal meat cellar operation).
ADJUSTING TEMPERATURE IN MULTI AND DUAL TEMPERATURE CABINETS
Multi and dual temperature cabinets allow setting different temperature levels inside
the same cellar in order to serve different types of wine.
To achieve maximum performance, the following temperature settings are suggested
for multi temperature cellars:
Bottom part: SP1 from +5°C to +7°C - (for dual 5°C/10°C) (For sliding door 6/10°C)
Top part: SP2 from +15°C to +18°C - (for dual +10°C to +18°C)
How to display and adjust temperature settings
Bottom part settings: SP1 from +5°C to +7°C - (for dual +5°C to +10°C)
Push
SET
for 5 seconds until the word
SP1
appears.
Push
SET
again and the programmed temperature of the lower zone will be visualized.
Modify programmed temperature by pushing buttons 2 and 3 ▼▲ and push
SET
again to
confirm.
Top part settings: SP2 from +15°C to +18°C - (for dual +10°C to +18°C)
To define the temperature of the upper zone push
SET
for some seconds until the word
SP1
appears. By pushing button 3▲ it will appear the word
SP2
. If you push
SET
again the pro-
grammed temperature of the upper zone will be visualized.
Modify programmed temperature by pushing buttons 2 and 3 ▼▲ and push
SET
again to
confirm.
Please note
that the number visualized on the display indicates the temperature of lower
zone. The small point in this position means that we are reading the programmed temperature
of the lower zone.
Dis. 1