Installation 

In most instances, it is desirable to use existing vehicle cables to connect uSTART

®

 to the vehicle starting and 

charging systems.  If new cables need to be made, the insulation should meet the requirements of SAE J1127, 
SAE J259, and TMC RP 166.  Recommended cable insulations are 125°C rated Cross-Linked Polyethylene 
(SAE J1127 type SGX) and 125°C rated Thermoset Elastomer (SAE J1127 type SGR where flexibility is 
required).  Selection of cable size is based on voltage drop requirements for a vehicle’s starting and charging 
systems.  Refer to TMC RP 105C to determine minimum cable size requirements.  

Mechanical 

It is desirable to install uSTART

®

 electrically closest to the starter or in the location where the starter cable is 

designed to terminate. However, the unit will perform well even installed remotely. Regardless, it must be 
installed electrically in parallel with at least one 12V battery using appropriately sized cables and hardware.  

Start from a point that all the cables both positive (+) and negative (-) are disconnected and fastened out of 
the way for installation or not installed in the vehicle yet. Install the battery(ies) and uSTART

®

 in their 

appropriate locations. 

When installing uSTART

®

 it is important to consider the battery hold down being used and how uSTART

®

 

relates to any batteries being mounted with it. 

uSTART is designed to be installed using the existing Group 31 battery hardware. Install uSTART using the 
existing Group 31 battery hardware and torque specifications. For custom installations please contact Ioxus 
Customer Service for additional support. 

Electrical 

Refer to the Wiring Diagrams section for typical vehicle wiring before and after uSTART

®

 installation. 

1.

 

Apply a thin coat of Noalox

®

 or similar anti-oxidizing compound for aluminum to the terminal pads of 

uSTART

®

 before installing any cables 

2.

 

Connect the vehicle positive (+) battery cable and Starter Solenoid positive (+) cable to the positive 
(+) terminal of uSTART

®

3.

 

Connect the vehicle positive (+) battery cable to the positive (+) terminal(s) of the battery(s). 

4.

 

Connect the vehicle negative (-) battery cable and Starter Solenoid negative (-) cable to the negative  
(-) terminal of uSTART

®

5.

 

Connect the vehicle negative (-) battery cable to the negative (-) terminal(s) of the battery(s). 

6.

 

The

 

solid

 

yellow LED

 

indicates that uSTART® is in 

Maintenance Mode

 and connected to a 

battery.   

7.

 

uSTART® is now ready to support the vehicle. uSTART® will automatically enter 

Run Mode

 when 

the vehicle starts. The 

yellow LED

 

flashes

 in 

Run Mode

 after a new uSTART® installation while 

uSTART® ultracapacitors are initially charged. Once the ultracapacitors are charged, 

Run Mode

 is 

denoted by a 

solid green LED

Содержание uSTART uST12D1100G31-ISA

Страница 1: ...Class 3 6 with 12V Operating System Table of Contents Model uST12D1100G31 ISA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre I...

Страница 2: ...r additional information Do not connect in reverse polarity uSTART is protected from reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attempted...

Страница 3: ...of damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational...

Страница 4: ...x is near the Diesel Particulate Filter After Treatment System or any part of the exhaust mount uSTART in a location far away from it or install heat shielding capable of preventing uSTART from experi...

Страница 5: ...ery ies and uSTART in their appropriate locations When installing uSTART it is important to consider the battery hold down being used and how uSTART relates to any batteries being mounted with it uSTA...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART instal...

Страница 7: ...low LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will still be in Maintenance Mode but the LEDs will be off If uSTART is not in Maintenance Mode when it is d...

Страница 8: ...ultracapacitors from a weak vehicle battery and provide power to jump start the vehicle Jump Start Mode can be accessed through the uSTART App The green LED will flash and the yellow LED will flash as...

Страница 9: ...Stadium Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 9 Run Mode Figure 5 Run Mode...

Страница 10: ...Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 10 Maintenance Mode Figure 6 Mainten...

Страница 11: ...m Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 11 Jump Start Mode Figure 7 Jump St...

Страница 12: ...ive heat shield may be worth installing between a heat source and the uSTART An environmental condition above 65 C 149 F will cause uSTART to enter Fault Mode in order to protect the product Prolonged...

Страница 13: ...TART has detected an abnormal internal condition causing it to enter fault mode No LED s On 1 Standby Mode This is a normal condition uSTART will enter Run Mode automatically when the vehicle is start...

Отзывы: